2018
DOI: 10.11607/jomi.5803
|View full text |Cite
|
Sign up to set email alerts
|

Mouthguard Biomechanics for Protecting Dental Implants from Impact: Experimental and Finite Element Impact Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
44
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(46 citation statements)
references
References 0 publications
1
44
0
1
Order By: Relevance
“…The results show that the presence of an MG is associated with a decrease in the stress magnitudes of teeth and maxilla bone but an increase in the soft tissue von Mises stresses. Though the simulated mouthguards had 4 mm of thickness, because some relevant studies described this parameter to be in the range of 3 to 4 mm as an ideal condition [8,[11][12][13]24,28], thinner mouthguards may have different results. Another design parameter that can condition the level of mouth protection is the mouthguard material.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The results show that the presence of an MG is associated with a decrease in the stress magnitudes of teeth and maxilla bone but an increase in the soft tissue von Mises stresses. Though the simulated mouthguards had 4 mm of thickness, because some relevant studies described this parameter to be in the range of 3 to 4 mm as an ideal condition [8,[11][12][13]24,28], thinner mouthguards may have different results. Another design parameter that can condition the level of mouth protection is the mouthguard material.…”
Section: Discussionmentioning
confidence: 99%
“…The stresses and stretches over the mouthguard reveal its ability to shock absorption, which depends in the material shock absorption ability. The EVA and the EVA foam materials show good energy absorption capabilities [1,8,9,14,28] and, therefore, all the three mouthguards are well positioned relatively to this parameter. Nevertheless, it was the HMG model that presented higher values of first principal stretches and lower values of third principal stretches, i.e., it shows greater elongation and compression, due to the flexibility of its outer layer, compared to FMG and CMG models.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…EVA is a thermoplastic copolymer, easily manipulated when heated. Additionally, it is considered non-toxic and easily available in the market [67,68]. This copolymer synthesis is conducted by high-pressure free radical polymerization of ethylene and vinyl acetate (VA) monomers resulting in a random copolymer [69][70][71].…”
Section: Ethylene Vinyl Acetate (Eva) Copolymermentioning
confidence: 99%
“…Custom‐made mouthguards have some advantages of optimal fit, retention, thickness, and extension plus they are the most comfortable interfering the least with oral function, since they are designed specifically for each patient 8,9 . Custom‐made mouthguards had adequate shore A hardness, which provides capacity to absorb energy generated during an impact 7 . A 4.0‐mm mouthguard thickness has high shock absorption and promotes lower stresses and strains in teeth and adjacent structures during an impact 3,9,10 .…”
Section: Introductionmentioning