Multi-objective optimal operation of hybrid AC/DC microgrid considering source-network-load coordination

Abstract: Taking the consumption rate of renewable energy and the operation cost of hybrid AC/DC microgrid as the optimization objectives, the adjustment of load demand curves is carried out considering the demand side response (DSR) on the load side. The complementary utilization of renewable energy between AC area and DC area is achieved to meet the load demand on the source side. In the network side, the hybrid AC/DC microgrids purchase electricity from the power grid at the time-of-use (TOU) price and sell the surpl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 34 publications
0
9
0
Order By: Relevance
“…Therefore, getting lines out of reach causes non-optimal alteration in the power generated by these units. Keeping this in mind, relations (5) and (6) show the vulnerability value of the generation unit u when the contingency related to the line k outage occurs. Looking at (5), once a fault in the grid occurs, if the generator power increases up to a normal level, then the generator's performance is vulnerable to the outage of line k. Therefore, evaluating the vulnerability of generators is dependent on the active power generation, with an emphasis on their max/min limitations of power.…”
Section: The Generation Unit Vulnerability Indicesmentioning
confidence: 99%
See 2 more Smart Citations
“…Therefore, getting lines out of reach causes non-optimal alteration in the power generated by these units. Keeping this in mind, relations (5) and (6) show the vulnerability value of the generation unit u when the contingency related to the line k outage occurs. Looking at (5), once a fault in the grid occurs, if the generator power increases up to a normal level, then the generator's performance is vulnerable to the outage of line k. Therefore, evaluating the vulnerability of generators is dependent on the active power generation, with an emphasis on their max/min limitations of power.…”
Section: The Generation Unit Vulnerability Indicesmentioning
confidence: 99%
“…To this end, the proposed hybrid microgrids can be useful in the relaxation of the grid variables using the power transaction described in Equations ( 38) and (39), which leads to a remarkable diminution in the generators' power, along with a lowering of the flowing power and voltage value as described in Equations ( 40) and (41). This results in the reduction of the vulnerability percentage while taking into account Equations ( 1), (3), (5), and (6). In sum, the proposed model comprises the objective function (32), (33), and (13) and the relevant constraints defined by equations (19) to (31) and (34) to (45).…”
Section: The Mathematical Formulation Of the Main Gridmentioning
confidence: 99%
See 1 more Smart Citation
“…This approach hierarchically covers three-level including DC microgrid, voltage source converter (VSC) stations and AC microgrids. In reference [6], a multiobjective optimization problem is presented which pursues two optimization objectives for the optimal operation of hybrid AC/DC microgrid. In [7], a two-step energy management process is proposed for AC/DC hybrid distribution network, which is considered as a multi-objective optimization problem for minimizing both the operation cost and energy loss.…”
Section: Introductionmentioning
confidence: 99%
“…Memetic algorithm has also been proposed in Ref. [18] for its separated local and global iterative process which guarantees convergence accuracy. Mixed Integer Linear Programming is another popular technique -it involves the use of some linearisation approach to convert the nonlinear models into linear models [11], [12], [19].…”
Section: Introductionmentioning
confidence: 99%