2018
DOI: 10.1016/j.chroma.2018.05.053
|View full text |Cite
|
Sign up to set email alerts
|

Multi-residue pesticide analysis in virgin olive oil by nanoflow liquid chromatography high resolution mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(24 citation statements)
references
References 35 publications
0
24
0
Order By: Relevance
“…In addition to PSA, 15 mg MWCNTs (particle size length: 10–50 μ m, outer diameter: 30–60 nm, and specific surface area: 280 m 2 ·g −1 ) was added to the Sin-QuEChERS Nano column. MWCNTs are nano hollow tubes with high mechanical strength, strong acid-base resistance, stronger adsorption, and purification capacity but do not affect the recovery rate of the target substance [ 23 25 ]. This experiment shows that the combination of PSA and MWCNTs can effectively remove impurities in the sample, reduce the interference to the target substance, improve the recovery rate of the target substance, and protect the analytical instrument from pollution and damage.…”
Section: Resultsmentioning
confidence: 99%
“…In addition to PSA, 15 mg MWCNTs (particle size length: 10–50 μ m, outer diameter: 30–60 nm, and specific surface area: 280 m 2 ·g −1 ) was added to the Sin-QuEChERS Nano column. MWCNTs are nano hollow tubes with high mechanical strength, strong acid-base resistance, stronger adsorption, and purification capacity but do not affect the recovery rate of the target substance [ 23 25 ]. This experiment shows that the combination of PSA and MWCNTs can effectively remove impurities in the sample, reduce the interference to the target substance, improve the recovery rate of the target substance, and protect the analytical instrument from pollution and damage.…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, due to the use of acetonitrile, the obtained extracts typically coextracted together with a large number of lipids, which may affect the stability and accuracy of the detection system and may reduce the lifetime of columns . Moreno-González used EMR-lipid as an additional cleanup step that removed most coextracted interferences. The innovative EMR-lipid technology removes lipids based on size exclusion and hydrophobic interaction mechanisms and can remove lipids and the matrix with high selectivity and efficiency.…”
Section: Resultsmentioning
confidence: 99%
“…The supernatant was subjected to cleanup using EMR‐lipids in d‐SPE. Good recoveries (75‐119%) were obtained for 162 multiclass pesticides .…”
Section: Sample Extraction and Cleanup Methodsmentioning
confidence: 96%