2013
DOI: 10.1016/j.jcis.2013.03.059
|View full text |Cite
|
Sign up to set email alerts
|

Multi-walled carbon nanotube modified carbon paste electrode as a sensor for the amperometric detection of l-tryptophan in biological samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
31
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 94 publications
(32 citation statements)
references
References 51 publications
1
31
0
Order By: Relevance
“…However, narrow peace and insufficient accuracy did not allow adequate description of these parts of the calibration curve. Separation of two linear pieces on calibration curves is frequently mentioned for differently modified electrodes and is commonly explained by two types of binding sites on their surface. In this work, higher sensitivity toward ultra‐small Trp concentrations can be described by their interaction with the silver ions in the pores of the coating partially filled with the Ag nanoparticles while higher analyte concentrations preferably interact with the surface of the film.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, narrow peace and insufficient accuracy did not allow adequate description of these parts of the calibration curve. Separation of two linear pieces on calibration curves is frequently mentioned for differently modified electrodes and is commonly explained by two types of binding sites on their surface. In this work, higher sensitivity toward ultra‐small Trp concentrations can be described by their interaction with the silver ions in the pores of the coating partially filled with the Ag nanoparticles while higher analyte concentrations preferably interact with the surface of the film.…”
Section: Resultsmentioning
confidence: 99%
“…Modification of the electrodes with mediators decreases working potential and improves performance of the sensor due to electrocatalytic effect and higher specific surface area. Thus, hemin , carbon nanotubes , ferrocene , Au nanoparticles , acetylene black , taken alone or in combination and included in electropolymerized matrices have been successfully used in the assembly of voltammetric sensors for the Trp determination. Although many of the above sensors show excellent sensitivity, the deposition of the sensing layer often involves several steps with rather complicated intermediate treatment of the surface.…”
Section: Introductionmentioning
confidence: 99%
“…In our continual effort to employ CPE and modified CPE for electroanalytical applications [31][32][33][34][35][36][37][38], in the present work, our aim was to fabricate a non-enzymatic sensor for Tyr. To achieve this, we have modified CPE by bulk modifying it using COOH-MWCNTs in the CPE matrix and employed it for the sensitive determination of Tyr in the presence of interfering molecules.…”
Section: Introductionmentioning
confidence: 99%
“…8 Furthermore, intaking the overdose of Try incites the dizziness, drowsiness, loss of appetite, nausea and hepatic disease. 9 The amount of Try present in the blood is very close relation with serotonin and melatonin, thus the Try was essential for mood enhancement, antidepressant and nutraceutical. 10 As a consequence, the researchers are devoted to develop a simple, selective, sensitive and highly efficient method for the determination of Try.…”
mentioning
confidence: 99%