DOI: 10.1016/j.clinbiochem.2015.07.032
|View full text |Cite
|
Sign up to set email alerts
|

Multicentric evaluation of eight glucose and four ketone blood meters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 21 publications
0
10
0
Order By: Relevance
“…Normally they are used for capillary blood by finger pricks (BHBc), but they may also be used for venous whole blood (BHBv). Several validation studies have compared different POC meters with standard laboratory analyses on plasma (BHBp) (5,12,15,27), and capillary POC testing has also been compared with liquid chromatography-tandem mass spectrometry on the same finger pricks (16). In general, the authors of these aforementioned studies conclude satisfactory performance of the POC meters, albeit with a tendency to underestimate concentrations over 3-4 mmol/L.…”
Section: Introductionmentioning
confidence: 99%
“…Normally they are used for capillary blood by finger pricks (BHBc), but they may also be used for venous whole blood (BHBv). Several validation studies have compared different POC meters with standard laboratory analyses on plasma (BHBp) (5,12,15,27), and capillary POC testing has also been compared with liquid chromatography-tandem mass spectrometry on the same finger pricks (16). In general, the authors of these aforementioned studies conclude satisfactory performance of the POC meters, albeit with a tendency to underestimate concentrations over 3-4 mmol/L.…”
Section: Introductionmentioning
confidence: 99%
“…These results suggest that neither breath acetone nor urinary ketone measurements accurately reflect the rapid changes in blood ketone concentrations after ketone drinks, and that blood measurement should be the preferred method to quantitatively describe ketosis. That said, it should be noted that although commercial handheld monitors are the most practical and widely available tool for measuring blood ketones, they can overestimate blood D-βHB compared to laboratory measures (Guimont et al, 2015 ) and these monitors do not measure L-βHB and so may not provide accurate total blood ketone concentrations, especially if a racemic ketone salt has been consumed.…”
Section: Discussionmentioning
confidence: 99%
“…Considering the potential for hyperketonemia to downregulate glycolysis and suppress adipocyte lipolysis, the optimal range of KB concentration to enhance substrate provision and energy production remains obscure. This is exacerbated by differences in the bioavailability of various ketone supplements and measurement discrepancy of point-of-care versus laboratory-based methods (Guimont et al, 2015;Leckey et al, 2017), thus making comparisons between studies difficult. For example, following the ingestion of the D-βHB R-1,3-butanediol monoester within a carbohydrate drink, plasma D-βHB was maintained above ∼2.0-3.0 mmol/L and improved performance during a preloaded 30-min cycling TT by ∼2% compared with the ingestion of an isoenergetic carbohydrate-only drink (Cox et al, 2016).…”
Section: Discussionmentioning
confidence: 99%