2007
DOI: 10.1016/j.talanta.2006.11.023
|View full text |Cite
|
Sign up to set email alerts
|

Multielement determination of trace metals in seawater by ICP-MS with aid of down-sized chelating resin-packed minicolumn for preconcentration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
55
0
1

Year Published

2007
2007
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 87 publications
(57 citation statements)
references
References 27 publications
1
55
0
1
Order By: Relevance
“…Unfortunately, only a few studies were carried out with suitable control procedures involving the overall experimental measurements. Often, the assessment of data quality was obtained only by calculating the percentage amounts of YLOID or Zr and Hf recovered from solutions in which the elemental concentration of the spikes added were higher with respect to their natural contents in seawater, or with the procedural blank composition not being clearly or exactly defined and not really simulating the seawater matrix [10][11][12][13][14]. Therefore, it is very problematic to compare the results obtained from different studies lacking the traceability of results of the complete analytical procedure that should be established using an appropriate Certified Reference Material (CRM).…”
Section: Introductionmentioning
confidence: 99%
“…Unfortunately, only a few studies were carried out with suitable control procedures involving the overall experimental measurements. Often, the assessment of data quality was obtained only by calculating the percentage amounts of YLOID or Zr and Hf recovered from solutions in which the elemental concentration of the spikes added were higher with respect to their natural contents in seawater, or with the procedural blank composition not being clearly or exactly defined and not really simulating the seawater matrix [10][11][12][13][14]. Therefore, it is very problematic to compare the results obtained from different studies lacking the traceability of results of the complete analytical procedure that should be established using an appropriate Certified Reference Material (CRM).…”
Section: Introductionmentioning
confidence: 99%
“…18,19 O pH da água do mar varia entre 7,4 e 8,4, devido principalmente ao efeito tampão do equilíbrio do sistema H 2 CO 3 / HCO 3 -/CO 3 2-. 20,21 Outra propriedade importante é a elevada condutividade devido aos sais dissolvidos.…”
Section: áGua Do Marunclassified
“…Inductively coupled plasma mass spectrometry (ICP-MS) has excellent analytical features such as simultaneous multi element detection capability, extremely high sensitivity, and wide linear dynamic range [1][2][3][4][5] . However, direct analysis of seawater by ICP-MS is still a difficult task, not only because the concentration levels of trace elements are quite low, but also because high salt matrix interfere with the determination.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, the present authors have reported a Chelex 100 resin-packed mini column method for pre-concentration and determination of 25 elements in seawater [4] using a small sample volume, where trace metals in 50 mL of original seawater sample were concentrated into 0.5 mL of 2 M nitric acid (final solution). From the results, it has been proved that the mini column is a convenient pre-concentration device for trace metals in seawater as well as in mineral waters prior to the determination by ICP-MS.…”
Section: Introductionmentioning
confidence: 99%