2023
DOI: 10.1021/acsomega.2c07338
|View full text |Cite
|
Sign up to set email alerts
|

Multilayer Heterogeneous Membrane Biosensor Based on Multiphysical Field Coupling for Human Serum Albumin Detection

Abstract: A factor closely associated with renal disease status in clinical diagnosis is abnormal human serum albumin (HSA) concentration levels in human body fluids urine, serum, etc. The surface stress biosensor was developed as a new type of biosensor to detect protein molecule concentration and has a wide range of clinical applications. However, further sensitivity improvement is required to achieve higher detection performance. Herein, MXene/PDMS/ Fe 3 O 4 /PDMS of the multilayer heterogeneous membrane biosensor (M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…To make silicon conductive, it can be easily doped with phosphorus or boron by ion implantation . PDMS is used as a membrane material due to its chemical stability, nontoxicity, high strain capability, and biocompatibility. Furthermore, PDMS has a very low Young’s modulus of approximately 1 MPa . As previously explained, membrane-based MEMS/NEMS biosensors represent a promising solution to address the limitations of cantilever-based MEMS/NEMS biosensors .…”
Section: Membrane-based Mems/nems Biosensors Based On Static Mode Tra...mentioning
confidence: 99%
“…To make silicon conductive, it can be easily doped with phosphorus or boron by ion implantation . PDMS is used as a membrane material due to its chemical stability, nontoxicity, high strain capability, and biocompatibility. Furthermore, PDMS has a very low Young’s modulus of approximately 1 MPa . As previously explained, membrane-based MEMS/NEMS biosensors represent a promising solution to address the limitations of cantilever-based MEMS/NEMS biosensors .…”
Section: Membrane-based Mems/nems Biosensors Based On Static Mode Tra...mentioning
confidence: 99%
“…Analytical Methods order to enhance the sensitivity of the ME exible biosensors, experiments were carried out to optimize the concentration of the ASFV P72 antibody. 24 The sensors modied with antibodies of 25 mg mL −1 , 50 mg mL −1 , 75 mg mL −1 , and 100 mg mL −1 were treated with 100 mg mL −1 of ASFV P72 antigen. As shown in Fig.…”
Section: Papermentioning
confidence: 99%