2014
DOI: 10.1063/1.4894025
|View full text |Cite
|
Sign up to set email alerts
|

Multiparameter measurement utilizing poloidal polarimeter for burning plasma reactor

Abstract: The authors have made the basic and applied research on the polarimeter for plasma diagnostics. Recently, the authors have proposed an application of multiparameter measurement (magnetic field, B, electron density, n e , electron temperature, T e , and total plasma current, I p ) utilizing polarimeter to future fusion reactors. In this proceedings, the brief review of the polarimeter, the principle of the multiparameter measurement and the progress of the research on the multiparameter measurement are explaine… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…The response time is orders of magnitudes above the typical dynamics of Cooper pairs generation-recombination and more in line with a bolometric regime. The detectors nevertheless fulfill the International Thermonuclear Experimental Reactor (ITER) response time guidelines of 10 ms [13] that have been taken into consideration during the design phase. We also checked the response of the pixels to radiation of two orthogonal polarizations.…”
Section: Prototypes Design and Characterizationmentioning
confidence: 99%
“…The response time is orders of magnitudes above the typical dynamics of Cooper pairs generation-recombination and more in line with a bolometric regime. The detectors nevertheless fulfill the International Thermonuclear Experimental Reactor (ITER) response time guidelines of 10 ms [13] that have been taken into consideration during the design phase. We also checked the response of the pixels to radiation of two orthogonal polarizations.…”
Section: Prototypes Design and Characterizationmentioning
confidence: 99%
“…Such schemes can become significantly more complex when recycling and pumping are taken into account using models [46] or even more complex when aiming for fully predictive profile control [47]. Towards ITER and future demonstration power plants, which also will have line integrated n e measurements [48][49][50], the main actuator will become deuterium (D) and tritium (T) pellet injection systems [51].…”
Section: Pedestal Density Control Schemementioning
confidence: 99%
“…The electron temperature has an effect on these measurements since the dielectric tensor depends on the electron temperature: So from these measurements an evaluation of the electron temperature can be carried out. The measurement of temperature can be extracted using an equilibrium code: An accuracy of 30% in the determination of Te was evaluated in [28].…”
Section: Measurement Of Electron Density By Interferometry-mentioning
confidence: 99%
“…This measurement is done by interferometrypolarimetry systems in the present day machines. In the ITER both toroidal [27] and poloidal [28] interferometer/polarimeters are planned. The experience on the toroidal interfero-polarimeter (TIP) was done on the tokamak JT-60U, where a dual wavelength (λ = 10.6 μm and 9.27 μm) CO 2 toroidal interfero-polarimeter [29] was extensively tested for the measurement of electron line integrated density using Faraday rotation.…”
Section: Measurement Of Electron Density By Interferometry-mentioning
confidence: 99%
See 1 more Smart Citation