Multiplex analysis of cytokines in exhaled breath condensate

Abstract: Background: To improve monitoring of lung diseases, we analyzed cytokines in exhaled breath condensate (EBC). The main challenge in measurement of cytokines in EBC is the low protein content, which requires concentration steps that conflict with the need for excessive fluid required by most commonly used kits. Methods: Here, a multiplex bead array for the detection of interleukins (IL) -1b, -6, -8, -10, TNF-a, and IL-12p70 was modified and validated for analysis in EBC samples. Furthermore, 33 healthy voluntee… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
78
1
4

Year Published

2006
2006
2016
2016

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 90 publications
(86 citation statements)
references
References 12 publications
3
78
1
4
Order By: Relevance
“…The overall level of detection was 46-97%, which was much better compared with cytometric bead array in small samples in children (,50%), and in large 1,000-2,000-mL lyophilisated samples in adults (3-100%) [6,[23][24][25][26]. When compared with conventional (solid-phase) immunoassays, multiplexed immunoassays detect bioactive and inactive molecules, have a growing analytical range, are rapid (take hours instead of days to perform), have good precision (CV 10-15%), are not interfered with by drugs, and have simple protocols [7].…”
Section: Discussionmentioning
confidence: 95%
“…The overall level of detection was 46-97%, which was much better compared with cytometric bead array in small samples in children (,50%), and in large 1,000-2,000-mL lyophilisated samples in adults (3-100%) [6,[23][24][25][26]. When compared with conventional (solid-phase) immunoassays, multiplexed immunoassays detect bioactive and inactive molecules, have a growing analytical range, are rapid (take hours instead of days to perform), have good precision (CV 10-15%), are not interfered with by drugs, and have simple protocols [7].…”
Section: Discussionmentioning
confidence: 95%
“…This may be overcome by lyophilisation, which enables removal water and other volatile substances, but may degrade biomarkers [ 53 ]. EBC lyophilisation can concentrate samples up to a factor of 30 times, thus improving sensitivity [ 61 ]. There was no relationship between EBC cytokine concentrations and storage times up to 1 year in samples stored at − 80 ° C [ 157 ].…”
Section: Cytokines Chemokines and Growth Factorsmentioning
confidence: 99%
“…Analysis of EBC has used a variety of sensitive methods, including ELISA [1], multiplex ELISAs [1] and, more recently, mass spectroscopy [2].…”
mentioning
confidence: 99%