2010
DOI: 10.1590/s0103-50532010000300010
|View full text |Cite
|
Sign up to set email alerts
|

Multiresidue determination of pesticides in carrots using pressurized liquid extraction and gas chromatography with mass spectrometry detector

Abstract: Neste estudo, 14 agrotóxicos (captan, clorotalonil, deltametrina, dicloran, fention, folpete, iprodiona, linurom, malationa, prometrina, procloraz, procimidona, triclorfom e trifluralina) foram usados no desenvolvimento de um método multiresíduos (MRM), utilizando extração de cenouras com líquido pressurizado (PLE). A etapa de clean-up foi realizada por dispersão da matriz em fase sólida (MSPD), sendo testados como material dispersante o Florisil, XAD-4, XAD-7 e C18. Diclorometano, acetato de etila e acetona f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 26 publications
0
2
0
Order By: Relevance
“…LOD is the lowest analyte concentration traceable in a sample by any analytical method. LOQ, in turn, represents the lowest analyte concentration that can be quantified at an acceptable level of precision, while still complying with the criteria of repeatability and precision. , The LOD and LOQ for AITC were determined by the signal/noise ratio, which in this research presented concentrations equal to 0.11 and 0.33 μg kg –1 , respectively. Currently, AITC is not registered for grain fumigation by any Brazilian regulatory agency, so there is no maximum residue limit (MRL) for this compound in stored products.…”
Section: Results and Discussionmentioning
confidence: 86%
“…LOD is the lowest analyte concentration traceable in a sample by any analytical method. LOQ, in turn, represents the lowest analyte concentration that can be quantified at an acceptable level of precision, while still complying with the criteria of repeatability and precision. , The LOD and LOQ for AITC were determined by the signal/noise ratio, which in this research presented concentrations equal to 0.11 and 0.33 μg kg –1 , respectively. Currently, AITC is not registered for grain fumigation by any Brazilian regulatory agency, so there is no maximum residue limit (MRL) for this compound in stored products.…”
Section: Results and Discussionmentioning
confidence: 86%
“…The LOD represents the lowest concentration of an analyte in a sample that can be detected, but not necessarily quantified, under the stated conditions of the test. The LOQ is the lowest concentration of an analyte in a sample that can be determined with acceptable precision and accuracy under the testing conditions [49,53].…”
Section: Validation Of the Methods Of Extraction And Analysismentioning
confidence: 99%