2001
DOI: 10.2172/814036
|View full text |Cite
|
Sign up to set email alerts
|

Multivariate High Order Statistics of Measurements of the Temporal Evolution of Fission Chain-Reactions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2001
2001
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…This could be due to fission products after neutron emission not being exactly 180 degrees apart. Mattingly's higherorder statistics development [15] allowed the quantitative determination of the fraction of californium fission counted in these types of chambers and showed that 4% of the fissions were not counted. This was determined by measuring the ratio of contributions to G 23 associated with the californium detection to G 23 , which contains contributions from undetected californium fissions.…”
Section: Californium Source Driven Noise Analysis Measurementsmentioning
confidence: 99%
“…This could be due to fission products after neutron emission not being exactly 180 degrees apart. Mattingly's higherorder statistics development [15] allowed the quantitative determination of the fraction of californium fission counted in these types of chambers and showed that 4% of the fissions were not counted. This was determined by measuring the ratio of contributions to G 23 associated with the californium detection to G 23 , which contains contributions from undetected californium fissions.…”
Section: Californium Source Driven Noise Analysis Measurementsmentioning
confidence: 99%
“…Thus, all the PMT bases that are shipped with the detectors must be modified in-house to operate with positive voltages. 11 Likewise, the ORTEC 556 detector power supplies can source either positive or negative voltages. To select positive voltage on this power supply, turn the polarity selector screw on the rear of the power supply to the positive position as shown in Figure 2.8.…”
Section: Detectors and Associated Electronicsmentioning
confidence: 99%
“…Thus, the third order correlation function including the Cf source channel may be used to separate the effects of Cf neutrons and inherent source neutrons. This may allow the separation of the effects of 240 Pu and 239 Pu and thus provide a estimate of the Pu isotopics 16 .…”
Section: Higher Order Correlationsmentioning
confidence: 99%