1999
DOI: 10.1002/(sici)1097-4695(199907)40:1<116::aid-neu10>3.0.co;2-m
|View full text |Cite
|
Sign up to set email alerts
|

N-methyl-D-aspartate receptor-mediated modulation of monoaminergic metabolites and amino acids in the chick forebrain: Anin vivo microdialysis and electrophysiology study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

6
21
0

Year Published

2000
2000
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(27 citation statements)
references
References 52 publications
6
21
0
Order By: Relevance
“…In the present study, NE was not detectable, but HVA as DA metabolite and 5HT and 5HIAA were detected. These results may, at least in part, reflect release of their respective neurotransmitters (Gruss and Braun, 1997;Gruss et al, 1999). Focusing on the variations in the basal values of DA content between the experiments, several studies (Saito et al, 2004;Shiraishi et al, 2010;Katayama et al, 2010Katayama et al, , 2011Erwan et al, 2012) have reported the fluctuation of monoamine contents especially in basal values of DA in the diencephalon or telencephalon in chicks.…”
Section: Discussionmentioning
confidence: 99%
“…In the present study, NE was not detectable, but HVA as DA metabolite and 5HT and 5HIAA were detected. These results may, at least in part, reflect release of their respective neurotransmitters (Gruss and Braun, 1997;Gruss et al, 1999). Focusing on the variations in the basal values of DA content between the experiments, several studies (Saito et al, 2004;Shiraishi et al, 2010;Katayama et al, 2010Katayama et al, , 2011Erwan et al, 2012) have reported the fluctuation of monoamine contents especially in basal values of DA in the diencephalon or telencephalon in chicks.…”
Section: Discussionmentioning
confidence: 99%
“…In previously proposed methods for combining a recording microelectrode with a microdialysis probe, a tungsten needle was glued to a guide cannula of a microdialysis (Gruss et al, 1999), a silver wire was inserted into a guide cannula (Obrenovitch et al, 1994), and a microdrive of bundled electrodes was glued to a guide cannula of a microdialysis probe (Ludvig et al, 1994). These methods of simply attaching a metal needle to a guide cannula are largely invasive due to the increment of probe's volume and make it difficult to precisely position the tip of recording microelectrodes to the target.…”
Section: Discussionmentioning
confidence: 99%
“…Earlier methods inserted a recording electrode into a guide cannula (Obrenovitch et al, 1994) or attached a recording electrode to a guide cannula, which were independently fabricated (Ludvig et al, 1994; Gruss et al, 1999). Our method, in which an electrode is fabricated directly on the surface of a guide cannula, is advantageous over these earlier methods.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Using separate electrodes to examine glutamate and electrophysiological signals within the same preparation has been a commonly employed method [19][20][21][22] ; however, it is problematic when the separate microelectrodes are not located within the same microenvironment. Several reports delivered external glutamate or drugs that could affect glutamate release into the rat brain and recorded only electrophysiological signal changes [23][24][25][26][27][28] ; however, this method can serve in only a limited capacity for glutamate change is not quantitative.…”
Section: Introductionmentioning
confidence: 99%