2014
DOI: 10.1007/s13738-014-0486-7
|View full text |Cite
|
Sign up to set email alerts
|

Nanoparticles-induced inflammatory cytokines in human plasma concentration manner: an ignored factor at the nanobio-interface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…Neutralizing the charge by surface modification of the nanosystem with other polymers or materials prevents binding of protein corona to the nanosystem and then activation of the immune response. Tirtatmadja et al observed that a variation of the protein corona composition at the nanosystem affected the production of IL-8 and TNF-α inflammatory cytokines [ 280 ]. Benita et al demonstrated that cationic group-coated PNs activated the immune response (inflammation) more than anionic group-coated PNs.…”
Section: Pharmacokinetics Biodistribution and Nanotoxicologymentioning
confidence: 99%
“…Neutralizing the charge by surface modification of the nanosystem with other polymers or materials prevents binding of protein corona to the nanosystem and then activation of the immune response. Tirtatmadja et al observed that a variation of the protein corona composition at the nanosystem affected the production of IL-8 and TNF-α inflammatory cytokines [ 280 ]. Benita et al demonstrated that cationic group-coated PNs activated the immune response (inflammation) more than anionic group-coated PNs.…”
Section: Pharmacokinetics Biodistribution and Nanotoxicologymentioning
confidence: 99%
“…Another unconsidered challenge in BMC studies is the inconsistency of the experimental environment and analysis methods employed in the related published articles. [ 114–116 ] For example, plasma concentration, [ 117,118 ] temperature, [ 96,119 ] incubation time, [ 96 ] pH, [ 96 ] type of separation method (e.g., in gel or on‐particle), [ 115 ] type of informatics database, and statistical analysis methods [ 115 ] are some of the parameters that differ widely in the published literature. To minimize these inconsistencies, Lynch and coworkers have suggested a guideline entitled “Minimum Information about Nanomaterial Biocorona Experiments (MINBE)” to enhance interoperability, reproducibility, and utility of BMC characterizations.…”
Section: The Challenges and Prospects Of Biomolecular Corona Consideration In Carbon‐based Nanomaterials Biodegradation Studiesmentioning
confidence: 99%
“…Thus the EMT nanosized zeolite can be considered as very promising material for purification of fibrinogen and lipoproteins, while keeping the highest concentration of albumin, when they are exposed to in vivo-like human plasma concentration. 181 Fibrinogen is a very complex, hydrophilic and bipolar molecule. In contrary to fibrinogen, apolipoprotein C-III (APOC-III) is a simple, highly hydrophobic and non-polar molecule.…”
Section: Biological and Medical Applications Of Nanosized Zeolitesmentioning
confidence: 99%