2020
DOI: 10.3390/polym12071497
|View full text |Cite
|
Sign up to set email alerts
|

Nanostructured Chitosan/Maghemite Composites Thin Film for Potential Optical Detection of Mercury Ion by Surface Plasmon Resonance Investigation

Abstract: In this study, synthesis and characterization of chitosan/maghemite (Cs/Fe2O3) composites thin film has been described. Its properties were characterized using Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) and ultraviolet-visible spectroscopy (UV-Vis). FTIR confirmed the existence of Fe–O bond, C–N bond, C–C bond, C–O bond, O=C=O bond and O–H bond in Cs/Fe2O3 thin film. The surface morphology of the thin film indicated the relatively smooth and homogenous thin film, and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
21
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 60 publications
(22 citation statements)
references
References 75 publications
1
21
0
Order By: Relevance
“…Hence, SPR can be used to monitor any binding event optically, and also for sensing applications. SPR was previously reported to have numerous advantages, such as fast measurement, no necessity for a reference solution, cost-effective, and simple sample preparation [ 97 ]. However, SPR has low sensitivity in sensing metal ions below 100 ppm.…”
Section: Methodsmentioning
confidence: 99%
“…Hence, SPR can be used to monitor any binding event optically, and also for sensing applications. SPR was previously reported to have numerous advantages, such as fast measurement, no necessity for a reference solution, cost-effective, and simple sample preparation [ 97 ]. However, SPR has low sensitivity in sensing metal ions below 100 ppm.…”
Section: Methodsmentioning
confidence: 99%
“…Surface plasmon resonance (SPR) strategy has drawn great attention as an economical, label-free tool because of its ability to detect target compounds in high sensitivity, real-time manner and rapid detection [ 42 , 43 , 44 , 45 , 46 , 47 , 48 ]. The Kretschmann configuration-based SPR method works by detecting the resonance in the form of charge density oscillations between the analyte and a metal thin film [ 49 , 50 , 51 , 52 , 53 , 54 , 55 ].…”
Section: Optical Sensorsmentioning
confidence: 99%
“…The light beam that passes through two different media with a higher to lower refractive index will be totally reflected if the incident angle is higher than the critical angle. The electromagnetic field component of the incident light will penetrate through the prism and reach the interface between the metal and dielectric medium to excite the free electron on the metal surface if the metal layer is thin enough [15][16][17][18][19][20][21][22]. As a result, the electron is excited and plasmon wave is formed that propagates along the metal surface.…”
Section: Introductionmentioning
confidence: 99%
“…In this study, the surrounding properties to generate SPR have been investigated using a simulation and automatic fitting program that has been developed using the Matlab program to achieve the best SPR signal. between the metal and dielectric medium to excite the free electron on the metal surface if the metal layer is thin enough [15][16][17][18][19][20][21][22]. As a result, the electron is excited and plasmon wave is formed that propagates along the metal surface.…”
Section: Introductionmentioning
confidence: 99%