2014
DOI: 10.15583/jpchrom.2014.006
|View full text |Cite
|
Sign up to set email alerts
|

Narrow Bore Packed Column Designed for Capillary Gas Chromatograph

Abstract: A narrow-bore packed column (packed-capillary column) that designed for a direct installation in conventional capillary gas chromatographic (GC) system had been developed. In this column, particulate sorbents that employed in typical GC packed columns were packed into a stainless-steel capillary of 1.0 mm i.d. By attaching a pair of stainless-steel capillaries of 1.27 mm o.d. at both ends of the column, the packed-capillary column can be directly installed into the conventional capillary GC system. In this art… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

6
2

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 31 publications
0
10
0
Order By: Relevance
“…These studies are currently underway in our laboratory including the interpretation of the retention mechanism on the basis of a molecular simulation [46][47][48]. Tanking into account a good heat resistance of the BF phase up to 300ºC and a good solvent resistance, the possibilities of the BF phase to the materials as the stationary phase in gas chromatography [49,50] and the extraction medium in sample preparation [51,52] are also investigated.…”
Section: Discussionmentioning
confidence: 99%
“…These studies are currently underway in our laboratory including the interpretation of the retention mechanism on the basis of a molecular simulation [46][47][48]. Tanking into account a good heat resistance of the BF phase up to 300ºC and a good solvent resistance, the possibilities of the BF phase to the materials as the stationary phase in gas chromatography [49,50] and the extraction medium in sample preparation [51,52] are also investigated.…”
Section: Discussionmentioning
confidence: 99%
“…Miniaturization of packed columns in GC [119][120][121][122][123] is also possible for high speed analysis with a unique selectivity but without a loss of sample loading capacity. …”
Section: Future Prospectivementioning
confidence: 99%
“…In packed-column GC, a wide variety of stationary phases can be employed [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25] including fine polymeric fibers having a good heat-resistance [13][14][15][16][17][18][19][20][21][22][23][24][25], and therefore, various types of volatile compounds having different polarities as well as permanent gases were successfully separated with a reasonable analysis time [10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25]. The sample loading capacity of the packed-column is also quite remarkable.…”
Section: Introductionmentioning
confidence: 99%