2014
DOI: 10.1021/nn500702g
|View full text |Cite
|
Sign up to set email alerts
|

Near-Infrared-Induced Heating of Confined Water in Polymeric Particles for Efficient Payload Release

Abstract: Near-infrared (NIR) light-triggered release from polymeric capsules could make a major impact on biological research by enabling remote and spatiotemporal control over the release of encapsulated cargo. The few existing mechanisms for NIR-triggered release have not been widely applied because they require custom synthesis of designer polymers, high-powered lasers to drive inefficient two-photon processes, and/or coencapsulation of bulky inorganic particles. In search of a simpler mechanism, we found that expos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
86
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 75 publications
(89 citation statements)
references
References 69 publications
3
86
0
Order By: Relevance
“…A study in BALB/c mice showed that 13nm-sized gold nanoparticles induced inflammation and apoptosis in liver tissue after 7 days [46]. Recently, a NIR actuated delivery system was designed where water was confined within poly (lactic-co-glycolic acid) (PLGA) particles and released fluorescein as the water was heated above the polymer's glass transition temperature [47]. A key strength of the system is the biocompatibility since PLGA is already used in FDA-approved implantable devices; however, the system is slow to respond as it takes 5 min of light exposure to trigger release and all light cycles occurred within 90 min.…”
Section: Discussionmentioning
confidence: 99%
“…A study in BALB/c mice showed that 13nm-sized gold nanoparticles induced inflammation and apoptosis in liver tissue after 7 days [46]. Recently, a NIR actuated delivery system was designed where water was confined within poly (lactic-co-glycolic acid) (PLGA) particles and released fluorescein as the water was heated above the polymer's glass transition temperature [47]. A key strength of the system is the biocompatibility since PLGA is already used in FDA-approved implantable devices; however, the system is slow to respond as it takes 5 min of light exposure to trigger release and all light cycles occurred within 90 min.…”
Section: Discussionmentioning
confidence: 99%
“…Fluorescence Lifetime Imaging-Fluorescence lifetime imaging microscopy (FLIM) was performed as described previously (40). Briefly, live COS-7 cells were imaged with a SliceScope two-photon microscope (Scientifica) using a 60ϫ water immersion objective (LUMPLFLN 60XW, NA ϭ 1.0, Olympus) and a Chameleon Ultra II IR laser (Coherent) tuned at 930 nm for the excitation of GFP.…”
Section: Methodsmentioning
confidence: 99%
“…7) [54]. Upon exposure to 980 nm NIR light, water molecules absorb optical energy through vibrational transitions, rapidly converting it into heat [55].…”
Section: Page 9 Of 25mentioning
confidence: 99%