2021
DOI: 10.3889/oamjms.2021.6840
|View full text |Cite
|
Sign up to set email alerts
|

Negative Correlation between Serum Brain-derived Neurotrophic Factor Levels and Obesity Predictor Markers and Inflammation Levels in Females with Obesity

Abstract: BACKGROUND: Obesity has been widely associated with structural and functional changes in the brain, whereas inflammation is one of the potential mechanisms involved in these changes. OBJECTIVE: This study aims to prove the relationship between serum brain-derived neurotrophic factor (BDNF) levels and obesity predictor markers (body mass index and waist to hip ratio) and inflammation (interleukin-6 and Tumor Necrosis Factor-alpha) levels in females with obesity. METHODS: This study used a cross-sect… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
6
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 41 publications
1
6
0
1
Order By: Relevance
“…The data collection process was carried out by taking anthropometric measurements which included height using a Stadiometer (Seca Corporation, CHINO, California, USA) (Rejeki et al, 2021), body weight using a digital scale (OMRON HN-289, Osaka, JAPAN) (Sugiharto et al, 2022). The calculation of body mass index (BMI) uses the formula of body weight (kg) divided by height (m 2 ) (Raharjo et al, 2021). Blood pressure (systolic and diastolic) was measured using an OMRON Deluxe Model HEM-8712 BASIC digital blood pressure meter (Puspodari et al, 2022).…”
Section: Study Participantsmentioning
confidence: 99%
“…The data collection process was carried out by taking anthropometric measurements which included height using a Stadiometer (Seca Corporation, CHINO, California, USA) (Rejeki et al, 2021), body weight using a digital scale (OMRON HN-289, Osaka, JAPAN) (Sugiharto et al, 2022). The calculation of body mass index (BMI) uses the formula of body weight (kg) divided by height (m 2 ) (Raharjo et al, 2021). Blood pressure (systolic and diastolic) was measured using an OMRON Deluxe Model HEM-8712 BASIC digital blood pressure meter (Puspodari et al, 2022).…”
Section: Study Participantsmentioning
confidence: 99%
“…Bodyweight was measured using a digital scale (OMRON HN-289, Osaka, JAPAN) (Sugiharto et al, 2022). BMI is calculated using body weight (kg) divided by body height (m 2 ) (Raharjo et al, 2021). Measuring blood pressure using a digital sphygmomanometer (OMRON Model Deluxe HEM-8712 BASIC, JAPAN) on the non-dominant arm 3 times in a row with a 2-minute rest interval between the two measurements, then the average value of the three measurements was taken (Andarianto et al, 2022;Raharjo et al, 2021).…”
Section: Study Organizationmentioning
confidence: 99%
“…BMI is calculated using body weight (kg) divided by body height (m 2 ) (Raharjo et al, 2021). Measuring blood pressure using a digital sphygmomanometer (OMRON Model Deluxe HEM-8712 BASIC, JAPAN) on the non-dominant arm 3 times in a row with a 2-minute rest interval between the two measurements, then the average value of the three measurements was taken (Andarianto et al, 2022;Raharjo et al, 2021). Measurement of heart rate rest (HR-rest) and oxygen saturation (SpO 2 ) using the Beurer Pulse Oximeter PO-30 (Rejeki et al, 2021).…”
Section: Study Organizationmentioning
confidence: 99%
“…Body weight was measured using a digital scale (OMRON HN-289, Osaka, JAPAN) (Sugiharto et al, 2022). BMI is calculated by dividing weight (kg) by height (m 2 ) (Raharjo et al, 2021). Measuring blood pressure using a digital sphygmomanometer (OMRON Model Deluxe HEM-8712 BASIC, JAPAN) on the non-dominant arm three times in a row with a 2-minute rest interval between the two measurements, then the average value of the three measurements is taken (Andarianto et al, 2022;Raharjo et al, 2021).…”
Section: Study Organizationmentioning
confidence: 99%
“…BMI is calculated by dividing weight (kg) by height (m 2 ) (Raharjo et al, 2021). Measuring blood pressure using a digital sphygmomanometer (OMRON Model Deluxe HEM-8712 BASIC, JAPAN) on the non-dominant arm three times in a row with a 2-minute rest interval between the two measurements, then the average value of the three measurements is taken (Andarianto et al, 2022;Raharjo et al, 2021). Measurement of horizontal leg muscle explosive power using the Standing Broad Jump (SBJ) Test (Tai et al, 2021), while measuring the explosive power of vertical leg muscles using the Jump Meter Digital (MD) Test.…”
Section: Study Organizationmentioning
confidence: 99%