2016
DOI: 10.1111/1365-2656.12515
|View full text |Cite
|
Sign up to set email alerts
|

Negative relationships between population density and metabolic rates are not general

Abstract: Population density has recently been suggested to be an important factor influencing metabolic rates and to represent an important 'third axis' explaining variation beyond that explained by body mass and temperature. In situations where population density influences food consumption, the immediate effect on metabolism acting through specific dynamic action (SDA), and downregulation due to fasting over longer periods, is well understood. However, according to a recent review, previous studies suggest a more gen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
44
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 32 publications
(46 citation statements)
references
References 29 publications
2
44
0
Order By: Relevance
“…The gut lengths (GL, mm, measured from the top of midgut to the bottom of hindgut when the animal is relaxed) of each individual as neonate and mature were measured using ImageJ v1.48 (National Institutes of Health, Bethesda, MD). These length measurements were then transformed to dry mass (DM, mg) using the following relationship between dry mass (DM) and gut length (GL): DM = 0.00679GL 2.75 (modified from Yashchenko et al ., ; see Appendix S1). Using dry mass of neonates (DM start ), dry mass at maturation (DM end ) and the number of days between the two measurements (duration), the somatic growth rate (SGR) was calculated as follows:SGR=lnDMendlnDMstartduration.…”
Section: Methodsmentioning
confidence: 99%
“…The gut lengths (GL, mm, measured from the top of midgut to the bottom of hindgut when the animal is relaxed) of each individual as neonate and mature were measured using ImageJ v1.48 (National Institutes of Health, Bethesda, MD). These length measurements were then transformed to dry mass (DM, mg) using the following relationship between dry mass (DM) and gut length (GL): DM = 0.00679GL 2.75 (modified from Yashchenko et al ., ; see Appendix S1). Using dry mass of neonates (DM start ), dry mass at maturation (DM end ) and the number of days between the two measurements (duration), the somatic growth rate (SGR) was calculated as follows:SGR=lnDMendlnDMstartduration.…”
Section: Methodsmentioning
confidence: 99%
“…The lengths of the animals (GL; gut length, measured from the apex of the foregut to the base of the hindgut) were measured to the nearest 0.01 mm using photographs from a stereo microscope (Leica Microsystems GmbH, Germany) and the software ImageJ (Rasband, ‐2016). Body masses (BM, dry weight, mg) were estimated by linear regression, using previously measured data on gut length (GL) and BM (Yashchenko, Fossen, Kielland, & Einum, ): BM = 0.00681 × GL 2.75 ( df = 30, r 2 = 0.99, p < .001). Details regarding the respirometric and the BM‐GL regression procedure are given by Yashchenko et al.…”
Section: Methodsmentioning
confidence: 99%
“…Details regarding the respirometric and the BM‐GL regression procedure are given by Yashchenko et al. ().…”
Section: Methodsmentioning
confidence: 99%
“…The microplate was integrated with a 24-channel fluorescence-based respirometry system (SDR Sensor Dish Reader) (PreSens Precision Sensing GmbH, Regensburg, Germany) that allows simultaneous measurement of 20 replicates and 4 controls (wells without animals). This respirometer is known for its simplicity, high throughput, and high temporal resolution and sensitivity [28,29]. The reader was placed inside the thermostatic cabinet at the appropriate testing temperatures (either 14 or 17 • C; accuracy: ±0.1 • C) 18 h before the beginning of the trials to bring the equipment and the standard water to the same temperature prior to measurements [20,29].…”
Section: Measurement Of Oxygen Consumptionmentioning
confidence: 99%
“…This respirometer is known for its simplicity, high throughput, and high temporal resolution and sensitivity [28,29]. The reader was placed inside the thermostatic cabinet at the appropriate testing temperatures (either 14 or 17 • C; accuracy: ±0.1 • C) 18 h before the beginning of the trials to bring the equipment and the standard water to the same temperature prior to measurements [20,29]. Twenty copepodids of D. belgicus were then individually loaded in the microwells that were in turn inspected for air bubbles under a stereomicroscope (Leica M80, Leica Microsystems Srl, Wetzlar, Germany) at 20× magnification.…”
Section: Measurement Of Oxygen Consumptionmentioning
confidence: 99%