2020
DOI: 10.1016/j.apenergy.2019.114031
|View full text |Cite
|
Sign up to set email alerts
|

Network-constrained thermal unit commitment for hybrid AC/DC transmission grids under wind power uncertainty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 41 publications
0
7
0
Order By: Relevance
“…[21], [28], [34], [35] [32], [33], [36], [38] Proposed model and load are regarded as the input data. Focus has been placed on the power flow of the ADS and the flexibility of the network such as power flow for AC/DC conversion, SOP, DTR, and DNR.…”
Section: A Modeling Of Ac/dc Hybrid Adssmentioning
confidence: 99%
See 3 more Smart Citations
“…[21], [28], [34], [35] [32], [33], [36], [38] Proposed model and load are regarded as the input data. Focus has been placed on the power flow of the ADS and the flexibility of the network such as power flow for AC/DC conversion, SOP, DTR, and DNR.…”
Section: A Modeling Of Ac/dc Hybrid Adssmentioning
confidence: 99%
“…Thus, the initial day-ahead dispatch is transformed into (36). Power flow limits: (1)-( 8) ( 26)-( 28) ( 32) (33) Voltage and current limits: ( 9)-( 11) RDG limits: ( 12)-( 14) ESS and SVC limits: ( 15)-( 20) VSC and SOP limits: ( 21) ( 23) ( 34) ( 35) (36) This equation is an SOCP problem and can be solved using commercial software such as CPLEX and GUROBI.…”
Section: B Solving Day-ahead Dispatchmentioning
confidence: 99%
See 2 more Smart Citations
“…• Power transmission over long distances [19]: Considering the effectiveness of high and medium-voltage DC lines, more power may be transferred over long distances, compared to their AC counterparts, owing to less severe stability issues. This feature makes DC integration into already existing AC grids extremely valuable for the future expansion of the grid and the connection of remote loads (such as in islands or isolated locations) or remote RES installations [20]. Major technological developments have enabled the increase of DC operating voltage levels in the order of kV, allowing efficient and reliable power transfer even for distances in the order of several thousands of kilometers.…”
Section: Driving Forces and Challenges For The Development Of Ac/dc Hybrid Smart Microgridsmentioning
confidence: 99%