Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Relevance. Today, keratorefractive surgery is a high-tech branch of ophthalmology and provides a predictable, high-precision, stable and safe refractive result in patients with a wide range of refractive disorders.Purpose. To evaluate the clinical and functional results of myopia correction using the technology of fractional lenticular extraction performed using femtosecond VisuMax and LDV Z8 lasers.Materials and methods. Within the framework of this work, 160 patients (160 eyes) with inpatient myopia of medium and high degree were examined and operated, with average keratometry parameters (43.0–45.0 dptr), aged from 18 to 36 years. The follow-up period was 1 month after the operation. The SMILE group was formed: a group of patients who underwent surgery using refractive lenticular extraction technology using a femtosecond VisuMax 500 laser (80 eyes); and the CLEAR group: a group of patients who underwent surgery using refractive lenticular extraction technology using femtosecond laser Femto LDV Z8 (80 eyes).Results and discussion. Operations with SMILE and CLEAR technology were performed in the Department of refractive laser surgery of the FSAU NMIC MNTC “Eye Microsurgery” named after S.N. Fedorov of the Ministry of Health of Russia (Moscow) according to standard protocols. No intraoperative complications were recorded. The analysis of comparable clinical and functional results of myopia correction using the technology of fractional lenticular extraction performed using femtosecond VisuMax and LDV Z8 lasers was carried out.Conclusion. Thus, the analysis of the clinical and functional results of correction of myopia of medium and high degree by the technology of refractive extraction of the lenticle performed using femtosecond lasers VisuMax and LDV Z8 showed their high comparability in terms of efficiency, safety, predictability and stability. A new technology of fractional lenticular extraction using a comprehensive assessment of the condition of the ocular surface at the preoperative stage, which allows to identify and eliminate the changes that have occurred, can be recommended for widespread clinical implementation.
Relevance. Today, keratorefractive surgery is a high-tech branch of ophthalmology and provides a predictable, high-precision, stable and safe refractive result in patients with a wide range of refractive disorders.Purpose. To evaluate the clinical and functional results of myopia correction using the technology of fractional lenticular extraction performed using femtosecond VisuMax and LDV Z8 lasers.Materials and methods. Within the framework of this work, 160 patients (160 eyes) with inpatient myopia of medium and high degree were examined and operated, with average keratometry parameters (43.0–45.0 dptr), aged from 18 to 36 years. The follow-up period was 1 month after the operation. The SMILE group was formed: a group of patients who underwent surgery using refractive lenticular extraction technology using a femtosecond VisuMax 500 laser (80 eyes); and the CLEAR group: a group of patients who underwent surgery using refractive lenticular extraction technology using femtosecond laser Femto LDV Z8 (80 eyes).Results and discussion. Operations with SMILE and CLEAR technology were performed in the Department of refractive laser surgery of the FSAU NMIC MNTC “Eye Microsurgery” named after S.N. Fedorov of the Ministry of Health of Russia (Moscow) according to standard protocols. No intraoperative complications were recorded. The analysis of comparable clinical and functional results of myopia correction using the technology of fractional lenticular extraction performed using femtosecond VisuMax and LDV Z8 lasers was carried out.Conclusion. Thus, the analysis of the clinical and functional results of correction of myopia of medium and high degree by the technology of refractive extraction of the lenticle performed using femtosecond lasers VisuMax and LDV Z8 showed their high comparability in terms of efficiency, safety, predictability and stability. A new technology of fractional lenticular extraction using a comprehensive assessment of the condition of the ocular surface at the preoperative stage, which allows to identify and eliminate the changes that have occurred, can be recommended for widespread clinical implementation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.