2016
DOI: 10.1007/s10008-016-3160-4
|View full text |Cite
|
Sign up to set email alerts
|

New acetaminophen amperometric sensor based on ferrocenyl dendrimers deposited onto Pt nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
10
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 64 publications
1
10
0
Order By: Relevance
“…On the other hand, were observed an oxidation peak around 0.4 V and a reduction peak in 0.0 V in the presence of 1.0 mmol L −1 of AC. In accordance with literature, the electrochemical mechanism of AC involves two protons and two electrons in a reversible or quasi‐reversible process depending on the working electrode [43, 47, 48]. In this case, the electrochemical redox mechanism of AC was quasi‐reversible due to the slow kinetics of the reaction at GCE and BiVO 4 ‐DHP/GCE, with ΔE p of 470 and 510 mV, respectively.…”
Section: Resultssupporting
confidence: 83%
See 1 more Smart Citation
“…On the other hand, were observed an oxidation peak around 0.4 V and a reduction peak in 0.0 V in the presence of 1.0 mmol L −1 of AC. In accordance with literature, the electrochemical mechanism of AC involves two protons and two electrons in a reversible or quasi‐reversible process depending on the working electrode [43, 47, 48]. In this case, the electrochemical redox mechanism of AC was quasi‐reversible due to the slow kinetics of the reaction at GCE and BiVO 4 ‐DHP/GCE, with ΔE p of 470 and 510 mV, respectively.…”
Section: Resultssupporting
confidence: 83%
“…In the literature, there are reports various methods AC determination using different analytical techniques such as spectrophotometry [36][37][38] and chromatography [39,40]. Electroanalytical methods are also reported utilizing different unmodified and modified carbon electrodes [28,30,[41][42][43][44][45][46][47][48][49][50][51][52][53][54][55]. Additionally, two works has been published in the literature involving the use of PEC sensors for AC determination.…”
Section: Introductionmentioning
confidence: 99%
“…As one can see, all electrodes in a non-aqueous solution (Figure A–C) show cathodic and anodic peak separations (Δ E p ) that are practically constant as the scan rate increases, and the Δ E p values are only marginally greater than zero (Table ). This fact indicates the absence of kinetic limitations. , In addition, a linear relationship between the peak currents and the scan rate was observed (insets in the graphs of Figure ), indicating the surface-confined nature of the ferrocenyl groups and the nonexistence of charge percolation. In other words, the films show behavior like that of a monolayer film …”
Section: Resultsmentioning
confidence: 98%
“…In addition, it can be concluded that the HNC-Rh-(ImS3-14) sensor presents good sensitivity and a low limit of detection in comparison to results recently published for similar studies ( Table 2). Given the fact that the sensor preparation is fast, easy and yields good analytical parameters, this represents a suitable method for paracetamol determination [25][26][27][28][29][30][31][32].…”
Section: Resultsmentioning
confidence: 99%