2017 IEEE PELS Workshop on Emerging Technologies: Wireless Power Transfer (WoW) 2017
DOI: 10.1109/wow.2017.7959359
|View full text |Cite
|
Sign up to set email alerts
|

New attachment method to increase the performance of ultrasonic wireless power transfer system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2025
2025

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…In APT literature, it is often claimed that the transmitted power is maximized when the characteristic acoustic impedance of the wall Z wall a equals the characteristic acoustic impedance of piezoelectric discs Z piezo a [5,40,[43][44][45]. This rule is justified by the fact that mechanical impedance mismatches lead to large reflections.…”
Section: Mechanical Impedance Issuesmentioning
confidence: 99%
See 1 more Smart Citation
“…In APT literature, it is often claimed that the transmitted power is maximized when the characteristic acoustic impedance of the wall Z wall a equals the characteristic acoustic impedance of piezoelectric discs Z piezo a [5,40,[43][44][45]. This rule is justified by the fact that mechanical impedance mismatches lead to large reflections.…”
Section: Mechanical Impedance Issuesmentioning
confidence: 99%
“…When an APT system using piezoelectric discs is built, transducers are generally connected to the wall using glue or acoustic couplant [20,36,40]. These additional layers affect the system's behavior and its efficiency.…”
Section: Impact Of Glue or Acoustic Couplant On Apt Performancesmentioning
confidence: 99%
“…As mentioned in Section 1, Bao et al, did not apply any AC-DC conversion circuit in their UTMWPT systems [15,16]. Systems presented by Leung et al could at best output only about 1.0 W of AC power [21]. Hu et al greatly simplified the UTMWPT system model in simulation and did not present experimental results [14].…”
Section: Measurementsmentioning
confidence: 99%
“…The simulation results showed a good consistency in trend with the experimental measurements. They also presented a spider clamp attachment method to bond the piezoelectric transducers to the metal wall in a UTMWPT system [21]. A prototype system built with this new attachment method was shown, which could, at best, transmit 1.0 W of power through a 1-mm-thick steel plate with an efficiency of 38%.…”
Section: Introductionmentioning
confidence: 99%