2008
DOI: 10.1055/s-2007-995677
|View full text |Cite
|
Sign up to set email alerts
|

New balloon-guided technique for deep small-intestine endoscopy using standard endoscopes

Abstract: BGE is safe. BGE enables deep intubation of the small bowel beyond the ligament of Treitz utilizing standard endoscopes. Insertion depth with this technique is beyond that achieved by push enteroscopy. Further studies are needed, and technical improvements will lead to deeper insertion.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
1

Year Published

2008
2008
2019
2019

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 6 publications
0
17
0
1
Order By: Relevance
“…A single-use double-balloon spiral overtube is available that can be mounted on most of the standard endoscopes, thus enabling push-and-pull manoeuvres [180]. Recent advances in endoscopic design include high definition imaging and optical or electronic structure enhancement of images, facilitating detection of subtle mucosal changes.…”
Section: What Is the Evidence Behind New Technology?mentioning
confidence: 99%
“…A single-use double-balloon spiral overtube is available that can be mounted on most of the standard endoscopes, thus enabling push-and-pull manoeuvres [180]. Recent advances in endoscopic design include high definition imaging and optical or electronic structure enhancement of images, facilitating detection of subtle mucosal changes.…”
Section: What Is the Evidence Behind New Technology?mentioning
confidence: 99%
“…Fortunately, this series revealed no severe complications during or after DBE procedures. Recently, singleballoon enteroscopy became available [34][35][36][37][38] . Whether single-balloon enteroscopy will be as useful for the investigation of small bowel disorders remains to be evaluated.…”
Section: Discussionmentioning
confidence: 99%
“…The BGE device compromises a two-balloon add-on disposable element and an air supply unit to control the inflation and deflation of the balloons [18]. The BGE also follows the push-and-pull principle, but in contrast to DBE and SBE the guidance during advancement into the small bowel is taken by the balloon, not by the endoscope.…”
Section: Diagnostic Work-up Of Small Bowel Diseasesmentioning
confidence: 99%
“…There are only preliminary data published on BGE showing limited insertion depth [18]. No comparing studies exist.…”
Section: Comparison Of the Different Flexible Enteroscopy Techniquesmentioning
confidence: 99%