“…Descriptions for quality assurance and quality control (QA/QC), including the field blank, spike recoveries, detection ratios, and instrument detection limit, are provided in Section S2 and Table S1. All samples were preprepared, extracted, purified, and analyzed at the Laboratory of the International Joint Research Center for Persistent Toxic Substances ( IJRC-PTS ), HIT, using processes described previously. , Eight NBFR compounds, pentabromotoluene (PBT), pentabromoethylbenzene (PBEB), hexabromobenzene (HBBz), 2,3-dibromopropyl 2,4,6-tribromophenyl ether (DPTE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (EHTBB), bis(2-ethylhexyl) tetrabromophthalate (BEHTBP), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), and decabromodiphenylethane (DBDPE), were quantified using an Agilent 7890B gas chromatograph (column: DB-5MS, 15 m × 0.25 mm × 0.1 mm, J&W Scientific) coupled with a 5977A mass spectrometer in the negative chemical ionization mode.…”