2020
DOI: 10.1016/j.msec.2019.110146
|View full text |Cite
|
Sign up to set email alerts
|

New inductive proximity sensor platform for precise localization of small colorectal tumors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
2
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 14 publications
0
8
0
Order By: Relevance
“…In an extensive previous research work 17 , five types of instruments incorporating different inductive proximity sensors 19 – 23 were constructed and extensively tested and optimized, with the aim to develop, verify and adopt the most appropriate clinical protocols for tumor detection. The process of development and construction, from watertight encapsulation of the inductive proximity sensor into stainless steel rods sheaths to fabrication of the electronic operation block module and elaboration of the swift connection between these two components is presented elsewhere 17 , 18 . The instrument was designed using a modular platform that allows widely-available sterilisation by autoclavation without damaging the electronic module.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…In an extensive previous research work 17 , five types of instruments incorporating different inductive proximity sensors 19 – 23 were constructed and extensively tested and optimized, with the aim to develop, verify and adopt the most appropriate clinical protocols for tumor detection. The process of development and construction, from watertight encapsulation of the inductive proximity sensor into stainless steel rods sheaths to fabrication of the electronic operation block module and elaboration of the swift connection between these two components is presented elsewhere 17 , 18 . The instrument was designed using a modular platform that allows widely-available sterilisation by autoclavation without damaging the electronic module.…”
Section: Methodsmentioning
confidence: 99%
“…Based on our previous research work 17 performed in gaseous (air) and liquid (0.9% NaCl, 5% Glucose solutions, etc.) environments, and continued on ex-vivo surgical specimens (animals and human) 18 , we have concluded that the 12 mm laparoscopic detecting system that incorporates a 10 mm diameter proximity sensor (IFS290 and E59M12C110C02-D1), offers the longest detection range and will be used in the “in-vivo” experiments.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The previous collaboration on two patents proposals: "Method and laparoscopic instrument for accurate position identification of colon tumour", OSIM, No. 2014 00821/03.11.2014 [27,28], and "Arterial puncture device for arterial blood gas sampling from radial artery and method for using the device", OSIM, No. A00475/13.07.2017 [29] and on four research papers [5,6,27,28], prove their ability to develop and identify new research opportunities applied directly to the rehabilitation of cardiac patients.…”
Section: Risk Predictionmentioning
confidence: 99%
“…2014 00821/03.11.2014 [27,28], and "Arterial puncture device for arterial blood gas sampling from radial artery and method for using the device", OSIM, No. A00475/13.07.2017 [29] and on four research papers [5,6,27,28], prove their ability to develop and identify new research opportunities applied directly to the rehabilitation of cardiac patients. Also, the expertise of the member of the project regarding the cardiac surgery and rehabilitation of cardiac patients, a top clinical and research centre from Romania, recommended it to be a valuable partner of this project.…”
Section: Risk Predictionmentioning
confidence: 99%