1992
DOI: 10.1080/00387019208018196
|View full text |Cite
|
Sign up to set email alerts
|

New Sensitive Method for the Analysis of Some Non UV Absorbing Quaternised Compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

1995
1995
2014
2014

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…Linearity of the TLCspectrodensitometric method was evaluated and it was found to lie within the concentration range of 2.0-12.0 µg.band -1 for HBB and 2.0-14.0 µg.band -1 for PAR, Figs. (3)(4). Good linearity was evident by the high value of the correlation coefficient and the low intercept value, (Table 4).…”
Section: Methods Validationmentioning
confidence: 99%
See 1 more Smart Citation
“…Linearity of the TLCspectrodensitometric method was evaluated and it was found to lie within the concentration range of 2.0-12.0 µg.band -1 for HBB and 2.0-14.0 µg.band -1 for PAR, Figs. (3)(4). Good linearity was evident by the high value of the correlation coefficient and the low intercept value, (Table 4).…”
Section: Methods Validationmentioning
confidence: 99%
“…Molecular formula C8H9NO2 Molar mass 440. 4 Molar mass 151.17 Many reported methods have been mentioned for the determination of HBB and PAR either separately or in combination with other drugs including spectrophotometric methods [2][3][4][5], chromatographic methods [6][7][8], electrochemical methods [9][10][11][12], Capillary electrophoresis methods [13,14] and titrimetric method [15][16][17].…”
Section: Molecular Formula C21h30brno4mentioning
confidence: 99%
“…The bottles were placed in an end‐over‐end rotator (Vanderkamp® Sustained Release Apparatus, Model 103906, VanKel Industries, Inc., Edison, NJ) in a 30°C temperature‐controlled water bath (Vanderkamp®, Model w‐1115, VanKel Industries, Inc.) and rotated at 30 RPM. After equilibration, the CTAB concentrations inside and outside of the dialysis bag were analyzed using a method modified from Mahrous et al13 A certain volume of the sample solution was taken and properly diluted. Five milliliters of the diluted solution was placed in a test tube and 10 mL of 0.01% picric acid in chloroform was added to the test tube.…”
Section: Methodsmentioning
confidence: 99%
“…There are many reports for the determination of HBB and DIP either separately or in combination with other drugs including spectrophotometric methods [2][3][4][5][6], chromatographic methods [7][8][9], electrochemical methods [10][11][12][13] ,Capillary electrophoresis methods [14,15] and titrimetric method [16][17][18] . .…”
Section: Introductionmentioning
confidence: 99%