2021
DOI: 10.1111/anec.12901
|View full text |Cite
|
Sign up to set email alerts
|

Night‐to‐night variability of sleep apnea detected by cyclic variation of heart rate during long‐term continuous ECG monitoring

Abstract: Sleep apnea is common among patients with cardiovascular diseases and a factor that could cause the diseases and worsen the prognosis. Sleep apnea causes repeated nocturnal hypoxia, increase in atrial and ventricular transmural pressure, and transient and sustained sympathetic nervous activation (

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 48 publications
(100 reference statements)
0
5
0
Order By: Relevance
“…These features would improve not only the ease of incorporating the sensor into bedding but also portability and practicality, reduce the burden of transfers between beds and patient rooms, and facilitate lending from the clinic to patients. Given the significant variability in sleep apnea severity from night to night [18], prolonged monitoring over multiple nights in a home setting is desirable to accurately assess the disease's characteristics in real-world conditions. In such scenarios, the small and lightweight design of the device becomes crucial for convenient handling and ensuring effective maintenance of cleanliness and hygiene.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…These features would improve not only the ease of incorporating the sensor into bedding but also portability and practicality, reduce the burden of transfers between beds and patient rooms, and facilitate lending from the clinic to patients. Given the significant variability in sleep apnea severity from night to night [18], prolonged monitoring over multiple nights in a home setting is desirable to accurately assess the disease's characteristics in real-world conditions. In such scenarios, the small and lightweight design of the device becomes crucial for convenient handling and ensuring effective maintenance of cleanliness and hygiene.…”
Section: Discussionmentioning
confidence: 99%
“…The method for measuring the heartbeat interval from ballistocardiogram is reported in Appendix. CVHR was detected by previously published algorithm [7,8,18] and Fcv and ECG-Fcv was computed as the frequency of CVHR per hour of TRT. The ECG-Fcv was used to determine whether the association between ballistocardiogram Fcv and AHI TRT is affected by the accuracy of ballistocardiogram-based heartbeat interval measurement.…”
Section: Analysis Of Fcvmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, episodes of sleep apnea may be accompanied by cyclic variation in heart rate; therefore, the estimation of sleep stages based on heart rate may be affected by sleep-disordered breathing. 20,21 In addition, frequent sleep stage shifts owing to respiratory events may increase the probability that GW3 incorrectly estimates sleep stages. Many participants who had difficulty maintaining sleep and had poor sleep quality were enrolled in this study, and these factors may have contributed to the erroneous estimation of GW3.…”
Section: Discussionmentioning
confidence: 99%
“…Secondly, we used CRM instead of polysomnography equipped with electroencephalography channels, which may provide a more detailed characterization of sleep patterns. A further limitation arises from the night-to-night AHI variability, which can at least in part confound the effects of sac/val (61). Moreover, although some patients can experience central apneas even at daytime, while awake and in the upright position (62,63), we chose to focus our attention only on nighttime registration, with the aim of increasing patient adherence.…”
Section: Discussionmentioning
confidence: 99%