1987
DOI: 10.1248/cpb.35.895
|View full text |Cite
|
Sign up to set email alerts
|

NMR evidence for the unexpected interconversion of 2-deoxy-2-fluoro-D-glucose and 2-deoxy-2-fluoro-D-mannose in mice.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

1991
1991
2004
2004

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(19 citation statements)
references
References 0 publications
0
19
0
Order By: Relevance
“…The supernatant was freeze-dried overnight and subsequently re-dissolved in 800 ml D 2 O prior to NMR analysis. 19 F NMR spectra of the tissue extracts were acquired at 470.59 MHz on either a Bruker DRX 500 (Birkbeck College) or a Varian Unity Plus 500 (Institute of Child Health), using an inverse gated sequence with proton decoupling. Acquisition parameters were as follows: 18 pulse angle, 1 s pulse delay, 0.78 s acquisition time, 42 016 Hz sweep width, temperature 300 K. The number of scans ranged from 2000 to 35 000.…”
Section: Fdg Metabolite Extractionmentioning
confidence: 99%
See 3 more Smart Citations
“…The supernatant was freeze-dried overnight and subsequently re-dissolved in 800 ml D 2 O prior to NMR analysis. 19 F NMR spectra of the tissue extracts were acquired at 470.59 MHz on either a Bruker DRX 500 (Birkbeck College) or a Varian Unity Plus 500 (Institute of Child Health), using an inverse gated sequence with proton decoupling. Acquisition parameters were as follows: 18 pulse angle, 1 s pulse delay, 0.78 s acquisition time, 42 016 Hz sweep width, temperature 300 K. The number of scans ranged from 2000 to 35 000.…”
Section: Fdg Metabolite Extractionmentioning
confidence: 99%
“…Quantification of metabolites was achieved by reference to a calibration curve of FDG concentration against relative peak area of FDG. This was constructed by acquiring 19 F NMR spectra of known concentrations of FDG (0.05-2 mM) and measuring the peak areas relative to the standard capillary containing 0.1 mM hexafluorobenzene. The equation of the line was determined and used for quantification of spectral peaks.…”
Section: Nmr Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…The 19 F NMR signal intensity of the CF 3 group of PFOA from organ was measured to determine the concentration. The quantification was performed by utilizing the calibration curve made by the benzene solution of trifluoroactamide (CF 3 CONH 2 ) after the correction of the measured signal intensity to the thermal equilibrated signal intensity according to the published method [20]. Briefly, the correction was performed for the filling factor of the sample tissue in the NMR detection coil and for the insufficient recovery of magnetization vectors after a pulse with the observed T 1 value of sample:…”
Section: F Nmr Measurementsmentioning
confidence: 99%