2002
DOI: 10.1016/s0041-624x(02)00214-7
|View full text |Cite
|
Sign up to set email alerts
|

Non-contact detection of laser-generated surface acoustic waves using fiber optic Sagnac interferometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 5 publications
0
11
0
Order By: Relevance
“…Note that the visibility of the surface-bonded fiber optic Sagnac sensor is twice better than that of noncontact type fiber optic Sagnac interferometer reported by Jang et al [7]. In the fiber optic Sagnac interferometer for noncontact measurement of ultrasound by Jang et al [6,7], the half amount of light comes out of the Sagnac loop through the dead port.…”
Section: Principle Of Surface-bonded Fiber Optic Sagnac Sensor For Ulmentioning
confidence: 91%
See 2 more Smart Citations
“…Note that the visibility of the surface-bonded fiber optic Sagnac sensor is twice better than that of noncontact type fiber optic Sagnac interferometer reported by Jang et al [7]. In the fiber optic Sagnac interferometer for noncontact measurement of ultrasound by Jang et al [6,7], the half amount of light comes out of the Sagnac loop through the dead port.…”
Section: Principle Of Surface-bonded Fiber Optic Sagnac Sensor For Ulmentioning
confidence: 91%
“…In the fiber optic Sagnac interferometer for noncontact measurement of ultrasound by Jang et al [6,7], the half amount of light comes out of the Sagnac loop through the dead port. In addition, a significant optical loss exists at the probing fiber, which is associated with reflection at a specimen surface and re-entering into the probing fiber core.…”
Section: Principle Of Surface-bonded Fiber Optic Sagnac Sensor For Ulmentioning
confidence: 99%
See 1 more Smart Citation
“…2,5,31,32 A design by this group based on a confocal Fabry-Perot interferometer significantly reduced the influence of the light collection system. Other approaches aimed at minimizing the effects of speckle structure include modifications of a Sagnac interferometer [33][34][35][36][37][38] and interferometer schemes employing photorefractive crystals. 31,[39][40][41] However, the detection sensitivity of all these optical techniques does not approach that of a well-designed, contact piezoelectric transducer.…”
Section: Introductionmentioning
confidence: 99%
“…1,3,4 For LU inspection of real composite structures used in the aerospace industry, reflections from rough surfaces must be processed effectively. To handle rough surfaces and simultaneously minimize the effects of environmental noise, we employed a Sagnac-based interferometer [33][34][35][36][37] measuring vibration speed instead of displacement. This approach has no reference arm.…”