Non‐Luer neuraxial equipment and anaesthetists’ attitudes to change

Abstract: efficacy of sugammadex in patients with a creatinine clearance of less than 30 ml.min )1 [4], but impaired renal function significantly reduced the plasma clearance of sugammadex and the sugammadex-rocuronium complex [5]. Recently, it was shown that neuromuscular blockade could be re-established with 1.2 mg.kg )1 rocuronium as early as 5 min after 4 mg.kg )1 sugammadex. Onset time and duration of neuromuscular blockade block varied according to the time interval between sugammadex reversal and re-administratio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
4
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…A survey of anaesthetists showed a desire for the same connector to be used for both spinals and epidurals within a hospital, even at the expense of their own personal preference for equipment [12]. There is considerably more complexity regarding epidural infusion administration equipment and potential incompatibility between local anaesthetic containers, pump giving sets and the epidural catheter than there is for spinal equipment [13].…”
Section: Discussionmentioning
confidence: 99%
“…A survey of anaesthetists showed a desire for the same connector to be used for both spinals and epidurals within a hospital, even at the expense of their own personal preference for equipment [12]. There is considerably more complexity regarding epidural infusion administration equipment and potential incompatibility between local anaesthetic containers, pump giving sets and the epidural catheter than there is for spinal equipment [13].…”
Section: Discussionmentioning
confidence: 99%
“…Of the 205 completed procedures, 14 were not successful with the first needle ( Table 3). Ten of these (5%) were real with problems with the packaging (4), the needle shaft (4) or the needle tip (2). There was little evidence to suggest that any of the problems were solely related to the connector, with the exception of the malformed Smiths' filter needle.…”
mentioning
confidence: 99%
“…When it became apparent that the deadline for spinal equipment would not be met, it was extended by one year. There still remains, though, a degree of ambivalence towards change . Many NHS trusts within the UK have chosen to defer complying with the alert until further data are available to guide their selection process, despite it being 18 months since the initial proposed implementation date for spinal equipment.…”
mentioning
confidence: 99%
See 1 more Smart Citation