2012
DOI: 10.1016/j.bios.2011.10.033
|View full text |Cite
|
Sign up to set email alerts
|

Nonenzymatic continuous glucose monitoring in human whole blood using electrified nanoporous Pt

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
44
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 87 publications
(44 citation statements)
references
References 29 publications
0
44
0
Order By: Relevance
“…Output signal through the fabricated glucose sensor was indicated from 0 to 1000 and we recorded the output signal. This signal and blood glucose level through the glucose analyzer (YSI 2300 STAT) was compared and calibrated by using linear regression analysis, which can be estimated based on equation [CG] = a x [OUT] + b, where CG is a calibrated glucose level, a is slope of calibration curve, OUT is output signal from glucose sensor, and b is a constant of calibration curve [20]. The parameter a and b were indicated to 0.2829 and 104.1611, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Output signal through the fabricated glucose sensor was indicated from 0 to 1000 and we recorded the output signal. This signal and blood glucose level through the glucose analyzer (YSI 2300 STAT) was compared and calibrated by using linear regression analysis, which can be estimated based on equation [CG] = a x [OUT] + b, where CG is a calibrated glucose level, a is slope of calibration curve, OUT is output signal from glucose sensor, and b is a constant of calibration curve [20]. The parameter a and b were indicated to 0.2829 and 104.1611, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Lee et al reported the detailed fabrication sequence of nafion membrane [19]. The nafion membrane, which is well-known as bio-compatible material and protective layer for biosensors, makes the glucose and interferences being oxidized on Pt surface without any morphological variation of Pt surface [20]. Fig.…”
Section: Instrumentmentioning
confidence: 99%
See 1 more Smart Citation
“…oxygen reduction reaction (ORR) [1][2][3][4], glucose oxidation [4][5][6][7][8][9], H 2 O 2 oxidation/reduction [2,4,10,11], pH measurement [12]), having wide applications such as fuel cell [1][2][3]6,13], chemical/biosensors [2,5,[7][8][9][10][11]14], pH sensor [12], and immunosensors [15]. Enhanced electroactivity of npPt compared to bulk Pt had been mainly attributed to its enlarged surface area [3,10,16].…”
Section: Introductionmentioning
confidence: 99%
“…The glucose content in normal human body is 3-8 mmol L −1 [1]. High blood glucose level can lead to diabetes and other complications such as heart diseases, kidney failure, and blindness [2,3]. On the contrary, it can make people dizzy, weak, and insensible when the blood glucose level is too low.…”
Section: Introductionmentioning
confidence: 99%