2021
DOI: 10.3390/s21216989
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive Blood Glucose Concentration Measurement Based on Conservation of Energy Metabolism and Machine Learning

Abstract: Blood glucose (BG) concentration monitoring is essential for controlling complications arising from diabetes, as well as digital management of the disease. At present, finger-prick glucometers are widely used to measure BG concentrations. In consideration of the challenges of invasive BG concentration measurements involving pain, risk of infection, expense, and inconvenience, we propose a noninvasive BG concentration detection method based on the conservation of energy metabolism. In this study, a multisensor … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…Furthermore, the early stopping method avoided over-training of the model. In comparison with [12,13,[15][16][17]21,[25][26][27], which served as the standard for predicting blood glucose, the proposed blood glucose estimation system had an MSE, RMSE, MAE, MARD, and R 2 of 40.736, 6.3824, 5.0896, 4.4321, and 0.997, respectively, all of which fell within region A of the Clarke EGA.…”
Section: Analyses and Discussion Of Network Experiments Resultsmentioning
confidence: 99%
“…Furthermore, the early stopping method avoided over-training of the model. In comparison with [12,13,[15][16][17]21,[25][26][27], which served as the standard for predicting blood glucose, the proposed blood glucose estimation system had an MSE, RMSE, MAE, MARD, and R 2 of 40.736, 6.3824, 5.0896, 4.4321, and 0.997, respectively, all of which fell within region A of the Clarke EGA.…”
Section: Analyses and Discussion Of Network Experiments Resultsmentioning
confidence: 99%
“…This headmounted monitor collects the photoelectric volume pulse wave signal, temperature, humidity, and thermal radiation temperature of the user's forehead or local tissue of human body, temperature and humidity of the surrounding environment for the user's forehead or the local tissue through using the re ected photoelectric volume pulse wave sensor measuring unit, temperature and humidity sensor measuring unit and thermal radiation temperature sensor measuring unit. These datas are used to estimate blood sugar levels by calculating the metabolic rate, oxygen saturation, pulse rate and blood ow velocity of the user's forehead or local tissue 46,47,48 .…”
Section: Measurement Of Noninvasive Blood Glucose Concentrationmentioning
confidence: 99%
“…We quote a non-invasive blood glucose concentration detection method 47 based on conservation of energy metabolism to test and verify the effectiveness and accuracy of the head-mounted monitor in detecting user's blood glucose. According to the method in References 47 , 40 volunteers were recruited for the experiment.…”
Section: Measurement Of Noninvasive Blood Glucose Concentrationmentioning
confidence: 99%
“…To measure blood glucose concentration, a mathematical model based on energy metabolism conservation was proposed [ 151 ]. To this end, a multisensor integrated diagnosis probe put on the wrist was developed.…”
Section: The Application Of ML and Dl Models For The Management Predi...mentioning
confidence: 99%
“…Back-propagation neural network (BPNN) and multivariate polynomial regression [151] 540 patients with T2DM…”
Section: Healthy Subjectsmentioning
confidence: 99%