2002
DOI: 10.1093/ilar.43.3.147
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive Cardiovascular Phenotyping in Mice

Abstract: With the growth of genetic engineering, mice have become common as models of human diseases, which in turn has stimulated the development of techniques to monitor and image the murine cardiovascular system. Invasive methods are often more quantitative, but noninvasive methods are preferred when measurements must be repeated serially on living animals during development or in response to pharmacological or surgical interventions. Because of the small size and high heart rates in mice, high spatial and temporal … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
47
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 64 publications
(48 citation statements)
references
References 60 publications
(88 reference statements)
1
47
0
Order By: Relevance
“…Transverse aortic banding was conducted in 12-week-old adult WT and ROCK-1 Ϫ/Ϫ mice, N Ն 6 mice for each group (39). Briefly, both ROCK-1 Ϫ/Ϫ and WT mice received a comparable load, based on the right-to-left carotid artery flow velocity ratio (from 5:1 to 10:1) after constricting the transverse aorta.…”
Section: Methodsmentioning
confidence: 99%
“…Transverse aortic banding was conducted in 12-week-old adult WT and ROCK-1 Ϫ/Ϫ mice, N Ն 6 mice for each group (39). Briefly, both ROCK-1 Ϫ/Ϫ and WT mice received a comparable load, based on the right-to-left carotid artery flow velocity ratio (from 5:1 to 10:1) after constricting the transverse aorta.…”
Section: Methodsmentioning
confidence: 99%
“…Noninvasive methods are used to study the effects of thyroid hormone on cardiac function and morphology (540,545,546). These methods are ideally suited for longitudinal analyses of individual animals.…”
Section: And Recommendation 49mentioning
confidence: 99%
“…For noninvasive measurements (including before banding) mice were anesthetized in a closed chamber with 3% isoflurane in oxygen for 2 to 5 minutes until immobile. Each mouse was then removed, weighed, and taped supine to ECG electrodes on a heated procedure board (MousePad, Indus Instruments, Houston, TX, USA) (Hartley et al, 2002) with isoflurane (initially at 2%) supplied by a nose cone connected to an anesthesia machine (Model V-1 with Isoflurane Vaporizer, VetEquip, Pleasanton, CA, USA). The board temperature was maintained at 35-37 °C.…”
Section: Animal Protocolmentioning
confidence: 99%