2003
DOI: 10.1029/2002jd002936
|View full text |Cite
|
Sign up to set email alerts
|

Nonmethane Hydrocarbon Intercomparison Experiment (NOMHICE): Task 4, ambient air

Abstract: [1] The Nonmethane Hydrocarbon Intercomparison Experiment (NOMHICE) was designed to assess the accuracy and comparability of nonmethane hydrocarbon (NMHC) measurements from research groups around the globe. This is being accomplished by conducting a series of intercomparisons, called Tasks, of prepared mixtures or collected ambient air. This paper presents results for an ambient air challenge sample as part of the fourth NOMHICE installment (Task 4). Twenty-three laboratories participated in Task 4, and 30 ove… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
54
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 45 publications
(57 citation statements)
references
References 28 publications
2
54
0
Order By: Relevance
“…This behavior has been observed by other laboratories measuring NMHC employing similar techniques (i.e. pre-concentration followed by GC-FID analysis) and is considered to be a product of detector and system parameters and configuration (Colman et al, 2001;Apel et al, 2003). Sample mixing ratios are determined from the individual compound response factors, with the exceptions being 3-methylpentane and cyclohexane, which are not in the primary standard.…”
Section: Standards and Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…This behavior has been observed by other laboratories measuring NMHC employing similar techniques (i.e. pre-concentration followed by GC-FID analysis) and is considered to be a product of detector and system parameters and configuration (Colman et al, 2001;Apel et al, 2003). Sample mixing ratios are determined from the individual compound response factors, with the exceptions being 3-methylpentane and cyclohexane, which are not in the primary standard.…”
Section: Standards and Calibrationmentioning
confidence: 99%
“…Additionally, for each sample meteorological parameters are calculated based on ECMWF re-analyzed data, and 8-day backward and 2-day forward trajectories are calculated with the KNMI trajectory model, TRAJKS (Scheele et al, 1996;van Velthoven, 2009) The experiences of other laboratories measuring NMHC from sampling canisters indicate that care should be taken to minimize the time between sample collection and analysis in order to avoid possible artifacts of storage (e.g. trace gas decomposition and growth of compounds) (Apel et al, 2003;Plass-Dülmer et al, 2006). With few exceptions, CARIBIC samples are analyzed for NMHC within two weeks of collection, and for the majority of flights analysis is conducted within one week.…”
Section: Sample Collectionmentioning
confidence: 99%
“…Here we used working standards collected in the Sierra Nevada mountain range. International intercomparison experiments have demonstrated that our analytical procedures consistently yield accurate identification of a wide range of blindly selected hydrocarbons and produce excellent quantitative results (e.g., Apel et al, 1999Apel et al, , 2003. Table 1 shows the limit of detection (LOD) and the measurement precision and accuracy for each VOC.…”
Section: Laboratory Analysis Of Vocsmentioning
confidence: 99%
“…Formal international comparisons between research groups using gas chromatography based systems for the measurement of non-methane hydrocarbons have been reported (Apel et al, 1994(Apel et al, , 1999(Apel et al, , 2003Slemer et al, 2002;Volz-Thomas et al, 2002). These studies demonstrated that different calibration standards and analytical procedures could lead to significant differences between laboratories in the analysis of synthetic mixtures and ambient air samples.…”
mentioning
confidence: 99%