2015
DOI: 10.3109/14764172.2015.1007062
|View full text |Cite
|
Sign up to set email alerts
|

Novel 755-nm diode laser vs. conventional 755-nm scanned alexandrite laser: Side-by-side comparison pilot study for thorax and axillary hair removal

Abstract: The new 755 nm diode laser is as effective and safe as the traditional 755 nm alexandrite laser. Additionally, treatment with the 755 nm diode laser with HR and SHR modes was found to be less painful.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
3

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 12 publications
0
7
0
3
Order By: Relevance
“…The concept of using low fluences at a high average power with a multiple pass in-motion technique was introduced for the 810-nm diode lasers, leading to a dramatic decrease in therapy-related pain, less discomfort and good efficacy [15][16][17]. The pain experienced by our patients was more significant than in the case presented by Paasch et al [7] because higher fluences were required to achieve the results obtained. However, we should stress the good tolerance of the in-motion method, in which the level of pain was comparable when applying much higher total accumulated energy than with the conventional method.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…The concept of using low fluences at a high average power with a multiple pass in-motion technique was introduced for the 810-nm diode lasers, leading to a dramatic decrease in therapy-related pain, less discomfort and good efficacy [15][16][17]. The pain experienced by our patients was more significant than in the case presented by Paasch et al [7] because higher fluences were required to achieve the results obtained. However, we should stress the good tolerance of the in-motion method, in which the level of pain was comparable when applying much higher total accumulated energy than with the conventional method.…”
Section: Discussionmentioning
confidence: 97%
“…On average, we consider that the clearances achieved were good in the context of the literature [7][8][9][10][11], and very good in comparison with our previous experience with other equipment [6,[12][13][14]. The efficacy percentages obtained appear lower than those achieved by Paasch et al in a single patient with more suitable hair removal characteristics, using lower (and less painful) fluences, with the same laser [7]. Paasch observed a clearance of 91.6% using the in-motion technique and 88.8% using the conventional technique.…”
Section: Discussionmentioning
confidence: 99%
“…Abzuwarten bleibt, ob mit fraktionalen Lasern wirklich bessere Therapieeffekte erreicht werden können, als es bisher mit qs-Systemen gelingt. Unabhängig davon sollten auch mit den fraktionalen CO 2…”
Section: Pigmententfernungunclassified
“…The latter are now also available with wavelengths of 755 nm and 1,064 nm . Based on initial studies, classic alexandrite lasers and the aforementioned novel diode lasers are almost identical with regard to efficacy and side effects .…”
Section: Epilationmentioning
confidence: 99%