2003
DOI: 10.2116/analsci.19.1387
|View full text |Cite
|
Sign up to set email alerts
|

Novel Imidazole PVC-Based Sensor Based on a Thiopyrilium Compound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
1

Year Published

2004
2004
2017
2017

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 24 publications
0
4
1
Order By: Relevance
“…Firstly, by considering the investigation, which had been conducted on the optimization of the membrane ingredients and, secondly, by selecting an appropriate plasticizer and a proper working pH range, the electrode presented a nice Nernstian behavior in a relatively wide concentration range? Additionally, the interfering of the other imidazole derivatives, unlike in the previous reported studies, 23,24 were diminished. In this work, according to the high sensitivity of the designed sensor and the selected pH, a mechanism based on the selectivity of the membrane toward His + derivatives has been described.…”
Section: Introductioncontrasting
confidence: 65%
See 1 more Smart Citation
“…Firstly, by considering the investigation, which had been conducted on the optimization of the membrane ingredients and, secondly, by selecting an appropriate plasticizer and a proper working pH range, the electrode presented a nice Nernstian behavior in a relatively wide concentration range? Additionally, the interfering of the other imidazole derivatives, unlike in the previous reported studies, 23,24 were diminished. In this work, according to the high sensitivity of the designed sensor and the selected pH, a mechanism based on the selectivity of the membrane toward His + derivatives has been described.…”
Section: Introductioncontrasting
confidence: 65%
“…22 This is most probably due to the soft-soft electrostatic interactions of the S + group of the ionophore and these anions. With imidazole, 23,24 this is likely because of the reaction of the ionophore with the imidazole molecule forming a dication, thus, presenting a slope of 25.5 mV decade -1 .…”
Section: Introductionmentioning
confidence: 99%
“…Histamine [265], histidine [266], imidazole [267,268], ketamine [269], ascorbic acid [270], oxalate [271], triamterene [272], naphazoline [273], valproate [274], cystein [275], theophiline [276], sulfosalicylic acid [277], thiosalicylic acid [278], salicylate [279,280], ketoconazole [281], clotrimazole [282], cimetidine [283], diclofenac [284], atenolol [285], picrate [286], linear alkylbenzene sulfonate [287,288], sodium dodecylsulfate [289][290][291], dodecylbenzene sulfonate [292] aresepecies the sensors of which have been introduced by Iranian researchers.…”
Section: Selective Electrodes For Drugs and Organic Speciesmentioning
confidence: 99%
“…As it is seen from Table 3, these sensors were based on ionophores like different complexes of iron(III) [265], iron(II) [270], copper(II) [271], zirconyl(IV) [277], nickel(II) [279], tin(IV) [280], lead(II) [275], aluminum(III) [278] and manganese(III) [265], 2,4,6- ClO 4 -, SCN -PME/ CGE [279] triphenylthiopyrilium perchlorate [267], 4-methyl-2,6-diphenylthiopyrylium [268], ion-exchanger sites [269], tetraphenylborate ion [272], tetraphenylborate [273], conducting polypyrrole films [274], 2,6-bis(phenyl)-4(phenyl) 3H-thiopyran [276], phthalocyanine [278], ketoconazoletetraphenyl borate ion pair [281], phosphomolybdate [282], phospoho tungstate [283], hexadecylpyridinium bromide [284], tetrakis(p-chlorophenyl) borate [285], polypyrrole [287,290], and hyamine [288], polyaniline-dodecylsulfate [289], cetylpyridinium cation [291], polyaniline [292], which have different natures and hence different selection mechanisms.…”
Section: Selective Electrodes For Drugs and Organic Speciesmentioning
confidence: 99%
“…The response time (95% of the final signal; T 95 ), which is one of the important factors for ISEs, was shorter then 10 s, when changing the concentration of silver ion from 1.0 × 10 -3 to 1.0 × 10 -2 mol dm -3 . It is known [19][20][21] slope of these derivatives based electrodes is considered to be due to the low solubility to a membrane solvent. It is therefore, expected that the lowering can be improved by introducing a lipophilic substituent into the derivatives.…”
Section: Fundamental Properties Of Electrodesmentioning
confidence: 99%