Proceedings of IEEE Sensors 2003 (IEEE Cat. No.03CH37498)
DOI: 10.1109/icsens.2003.1278935
|View full text |Cite
|
Sign up to set email alerts
|

Novel inductive eddy current sensor for angle measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 1 publication
1
3
0
Order By: Relevance
“…Linearity gives an indication of how close the calibration curve fits a straight line. The maximum deviation above and below the straight line, V MT and V MB , and the total displacement (∆x), are used to determine linearity, as given by (5). The simulation results shown in Figure 4 support the sensor operation described previously.…”
Section: Modellingsupporting
confidence: 63%
See 1 more Smart Citation
“…Linearity gives an indication of how close the calibration curve fits a straight line. The maximum deviation above and below the straight line, V MT and V MB , and the total displacement (∆x), are used to determine linearity, as given by (5). The simulation results shown in Figure 4 support the sensor operation described previously.…”
Section: Modellingsupporting
confidence: 63%
“…Sensing coils are not connected to the excitation coil and a change in induced voltage can be measured using analog to digital converters. These sensors are commonly used to measure lateral displacement [4], rotation [5] and axial displacement [6]. It is also used to detect defects in materials like PCBs [7] and is highly dependent on material properties [8].…”
Section: Introductionmentioning
confidence: 99%
“…Grating eddy current displacement sensor uses multi-layer hollow planar coils as stimulators to generate eddy current in conductors and inducts variation of intensity of eddy current and finally outputs electronic signals correlated with lateral displacement [1][2][3]. This kind of sensor has some advantages such as wide measurement range, high sensitivity, and strong resistance against oil or water, etc.…”
Section: Introductionmentioning
confidence: 99%
“…In view of the characteristics of the GECS mentioned above, to overcome the low accuracy of coarse localization of a double-track PDGECS and to avoid large size or complicated structure of a PDGECS, a GECS, the operational principle of which is based on the phase of one track and the code of the other track, is described in this paper (hereinafter, this kind of sensor will be referred to as a combinatorial code grating eddy-current sensor (CCGECS)). The method with phase of one track as precise localization of the PDGECS is adopted by the CCGECS, but the coarse-localization method is improved by using single-track code to realize coarse localization as a replacement of phase difference among multiple tracks as coarse localization of the PDGECS [7][8][9]. The measurement principle of the CCGECS is introduced in section 2.…”
Section: Introductionmentioning
confidence: 99%