2012
DOI: 10.1109/lpt.2012.2226876
|View full text |Cite
|
Sign up to set email alerts
|

Novel NCF-FBG Interferometer for Simultaneous Measurement of Refractive Index and Temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(22 citation statements)
references
References 12 publications
0
22
0
Order By: Relevance
“…To improve the accuracy of the RI measurement, the temperature induced wavelength shift must be precisely subtracted from the total amount of wavelength shift jointly induced by the temperature and RI change. A common way is to add another temperature sensor and measure the two parameters simultaneously [12][13][14][15].…”
Section: Working Principlesmentioning
confidence: 99%
See 1 more Smart Citation
“…To improve the accuracy of the RI measurement, the temperature induced wavelength shift must be precisely subtracted from the total amount of wavelength shift jointly induced by the temperature and RI change. A common way is to add another temperature sensor and measure the two parameters simultaneously [12][13][14][15].…”
Section: Working Principlesmentioning
confidence: 99%
“…In Ref. [12][13][14][15], fiber Bragg grating temperature sensors were used along with SMS-based refractometers to compensate the temperature-induced influence. In Ref.…”
Section: Introductionmentioning
confidence: 99%
“…To solve the RI-temperature crosstalk problem, various methods have been proposed [16][17][18][19][20][21]. One of the most common and effective methods is to introduce an FBG [16][17][18][19], which is sensitive to temperature but not to surrounding RI.…”
Section: Introductionmentioning
confidence: 99%
“…One of the most common and effective methods is to introduce an FBG [16][17][18][19], which is sensitive to temperature but not to surrounding RI. The temperature can be compensated even to realize the simultaneous measurement of RI and temperature by monitoring two dips, which are induced by FBG and MMI respectively in the transmission spectrum of sensor.…”
Section: Introductionmentioning
confidence: 99%
“…Manuscript On the other hand, simultaneous measurement of temperature and refractive index (RI) is very important in many applications, especially in chemical or food industries for quality control and in environmental industries for contamination assessment. Because the resonant wavelength of a FBG inscribed on a standard single-mode fiber (SMF) is susceptible to temperature while not to surrounding RI, FBGs have also been widely used to realize the simultaneous measurement of temperature and RI when cascaded with another RI sensor [5][6][7][8][9][10]. Nevertheless, in these cases, either a special fiber (such as no-core fiber [5], and etched multimode fiber [6]) or a special structure (such as an external Fabry-Perot cavity [7], a pair of long period fiber gratings with the same parameters [8], core-offset Mach-Zehnder interferometer [9], and Up-Fusion-Bitaper pair [10]) is needed to construct a refractometer.…”
Section: Introductionmentioning
confidence: 99%