2021
DOI: 10.3934/matersci.2021036
|View full text |Cite
|
Sign up to set email alerts
|

Numerical and experimental investigation of concrete with various dosages of fly ash

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…The internal pressure of 414 KPa is also applied to the internal surface of the GPC pipe model. It is urgent to point out that the mechanical properties of the GPC pipe, such as the compressive strength and density made from PC with diverse dosages of 0, 10, 20, 30, 50, and 70% FA as replacement of PC weight were experimentally obtained in this study (Tables 11-13), along with the 9 parameters related to the nonlinear state of the GPC calibrated in this investigation (Table 14) [3,50].…”
Section: Static Analysis Of Gpc Underground Pipementioning
confidence: 94%
See 3 more Smart Citations
“…The internal pressure of 414 KPa is also applied to the internal surface of the GPC pipe model. It is urgent to point out that the mechanical properties of the GPC pipe, such as the compressive strength and density made from PC with diverse dosages of 0, 10, 20, 30, 50, and 70% FA as replacement of PC weight were experimentally obtained in this study (Tables 11-13), along with the 9 parameters related to the nonlinear state of the GPC calibrated in this investigation (Table 14) [3,50].…”
Section: Static Analysis Of Gpc Underground Pipementioning
confidence: 94%
“…The internal pressure of 414 KPa is also applied to the internal surface of the GPC pipe model. It is urgent to point out that the mechanical properties of the GPC pipe, such as the compressive strength and density made from PC with diverse dosages of 0, 10, 20, 30, 50, and 70% FA as replacement of PC weight were experimentally obtained in this study (Tables 11-13), along with the 9 parameters related to the nonlinear state of the GPC calibrated in this investigation (Table 14) [3,50]. 9, the applied traffic load is used as the uniform contact pressure with the value of 74,137 N/m 2 on the top surface of the backfill soil which is exactly located on the fault considered in the middle position of the GPC pipe as well (Figure 16).…”
Section: Static Analysis Of Gpc Underground Pipementioning
confidence: 96%
See 2 more Smart Citations