“…In our previous work [14], the StarCCM+ commercial CFD code was applied to the analysis of an HV-like geometry adopting deep rectangular cavities 1 with aspect ratio (AR) = depth/width = 3, which has already been used in several gyrotron tubes 2 . While for steady state heat load up to 5 MW/m 2 this solution proved to be acceptable, concerning the capability to keep the collector below a maximum acceptable Cu temperature of 300 • C, when the actual transient heat load was considered (in combination with a vertical sweeping scenario) this threshold was overcome.…”