2022
DOI: 10.1016/j.buildenv.2022.109486
|View full text |Cite
|
Sign up to set email alerts
|

Numerical investigation of the flow behavior of an isothermal corner impinging jet for building ventilation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 28 publications
1
7
0
Order By: Relevance
“…( 10)- (11). As for the latter group of indoor moist air, it is acquired from the available reference [39,40] that its flow belongs to the complicated turbulence that enables to rapidly homogenize interior temperature. Given that primary aims of this investigation are to assess capacity of the active phase change heater and related thermal performance of built buildings from the aspect of energy conservation, therefore the entire internal space is assumed as an isothermal domain with the transient mean temperature marked as the performance index.…”
Section: Moist Airmentioning
confidence: 99%
“…( 10)- (11). As for the latter group of indoor moist air, it is acquired from the available reference [39,40] that its flow belongs to the complicated turbulence that enables to rapidly homogenize interior temperature. Given that primary aims of this investigation are to assess capacity of the active phase change heater and related thermal performance of built buildings from the aspect of energy conservation, therefore the entire internal space is assumed as an isothermal domain with the transient mean temperature marked as the performance index.…”
Section: Moist Airmentioning
confidence: 99%
“…The turbulence model for this study was chosen based on a previous study [12] that tested three different types of turbulence models, RNG k − ε, SST k − ω, and v 2 − f , in order to evaluate their viability of predicting the impinging jet flow fields. Hence, the RNG k − ε was chosen as the turbulence model in this study based on the result of that study, which is also similar to some other studies that have evaluated the impinging jet settings [13][14][15].…”
Section: Turbulence Modelsmentioning
confidence: 99%
“…The base model used in this study is from a previous study and was validated by Ameen et al [12]. An experimental comparison was made between the CFD model and an experimental setup, which compared the air velocity profiles measured at different locations along the centerline of the floor surface, specifically at distances of 0.225, 0.3, 0.5, 0.7, and 1 m from the inlet.…”
Section: Cfd Validationmentioning
confidence: 99%
See 1 more Smart Citation
“…To solve these problems, this research group put forward a new air supply mode for a powerhouse in the tall space of an underground hydropower station combined with a vertical wall-attached air supply mode. Recently, jet ventilation has gained scholarly attention due to high momentum and favorable flow pattern [21][22][23], including impinging jet ventilation [24,25], attached plane jets, confluent jet ventilation and so on [26][27][28]. Compared with other air supply methods, the total cooling load borne by an attached air supply is smaller, which saves energy and does not affect the net height of a space.…”
Section: Introductionmentioning
confidence: 99%