2016
DOI: 10.1002/cnm.2852
|View full text |Cite
|
Sign up to set email alerts
|

Numerical simulation of volume‐controlled mechanical ventilated respiratory system with 2 different lungs

Abstract: Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dyna… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
29
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 27 publications
(31 citation statements)
references
References 15 publications
2
29
0
Order By: Relevance
“…Cough Frequency. According to the second part, even if there exist a variety of patterns of coughing making it difficult to identify and quantify cough, coughing can be quantified in four different ways [22]:…”
Section: Endpoints Of Objective Cough Assessmentmentioning
confidence: 99%
“…Cough Frequency. According to the second part, even if there exist a variety of patterns of coughing making it difficult to identify and quantify cough, coughing can be quantified in four different ways [22]:…”
Section: Endpoints Of Objective Cough Assessmentmentioning
confidence: 99%
“…The development of the non-oil system is required in the development of the electric-pneumatic pressure proportional valves. With the extensive research of self-lubrication special material and gas film lubrication, its unique lubricity can be applied to an oil-free system, which provides the idea for oil-free system [71][72][73][74][75][76].…”
Section: Oil-freementioning
confidence: 99%
“…Thus, the performance holding of EHS under these uncertain nonlinearities is still a challenge problem in EHS control loop. By the way, the parametric uncertainty and noise disturbance also obviously exist in pneumatic system such as mechanical ventilation [8][9][10][11][12][13][14][15][16][17], network distributed control plant [18,19], multiple-input single-output processes [20].…”
Section: Introductionmentioning
confidence: 99%