2020
DOI: 10.1016/j.jhazmat.2020.122742
|View full text |Cite
|
Sign up to set email alerts
|

Occurrence and Trophic Magnification of Organophosphate Esters in an Antarctic Ecosystem: Insights into the Shift from Legacy to Emerging Pollutants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
43
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 61 publications
(46 citation statements)
references
References 78 publications
3
43
0
Order By: Relevance
“…Three plastic bags (food-grade polyethylene) that were used for fishmeal storage were cut in to 1 cm pieces and extracted using acetonitrile for OPE detection. Detail pretreatment process is described in our previous study . TMP, TEP, TPrP, TPhP, TBOEP, TMTP, TOTP, TPTP were not detected in any of the three plastic bags.…”
Section: Methodsmentioning
confidence: 67%
See 1 more Smart Citation
“…Three plastic bags (food-grade polyethylene) that were used for fishmeal storage were cut in to 1 cm pieces and extracted using acetonitrile for OPE detection. Detail pretreatment process is described in our previous study . TMP, TEP, TPrP, TPhP, TBOEP, TMTP, TOTP, TPTP were not detected in any of the three plastic bags.…”
Section: Methodsmentioning
confidence: 67%
“…Tri-OPEs and di-OPEs were extracted and purified separately. Tri-OPEs were analyzed following previous studies with some modification. , Briefly, 1.0 g of fishmeal was weighed into a 15 mL Corning centrifuge tube, spiked with surrogate standard (1 ng), and aged overnight. Sonication assisted extraction was performed for 30 min using 5 mL acetonitrile/toluene ( v : v = 9:1) with 0.5% formic acid.…”
Section: Methodsmentioning
confidence: 99%
“…The analytical procedures of the OPEs referred to previous studies with minor modifications. , Briefly, 0.5 g of homogenized APF sample was weighed into a 15 mL Corning centrifuge tube and spiked with 100 μL labeled internal standard (10 ng/mL for each chemical). The backgrounds of OPEs in the Corning centrifuge tube and other materials have been evaluated by a previous study and proved satisfied for OPE analysis . It was then aged overnight at room temperature.…”
Section: Materials and Methodsmentioning
confidence: 99%
“…The backgrounds of OPEs in the Corning centrifuge tube and other materials have been evaluated by a previous study and proved satisfied for OPE analysis. 19 It was then aged overnight at room temperature. The extraction was carried out by adding 5 mL acetonitrile/toluene (9:1, v/v) containing 0.5% formic acid, subsequently vortex mixed for 1 min and ultrasonic extracted for 30 min.…”
Section: Sample Collection and Analysismentioning
confidence: 99%
See 1 more Smart Citation