2016
DOI: 10.20965/ijat.2016.p0494
|View full text |Cite
|
Sign up to set email alerts
|

Omnidirectional Soft Robot Platform with Flexible Actuators for Medical Assistive Device

Abstract: This manuscript explains the employment of flexible actuators to act as a soft robot and transporting agent to assist medical X-ray examinations. Although soft robots from silicone material can be transparence and a human compliance used as medical assistive devices, soft robots have some problems: they tend to be sluggish, have long and imprecise gait trajectories, and need their control parameters to be adjusted for motion diversion. A soft robot with omnidirectional locomotion has been created, one that has… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 20 publications
0
3
0
Order By: Relevance
“…The soft actuator composition also covers the artificial pneumatic gel muscles (PGMs) utilized to examine the muscle loading and unloading effects for all motions of the upper limb [19]. Some research utilizes soft robots during fluoroscopy and x-ray examinations, including pneumatic flexible microactuator (FMA)-based towel or pillow controlled with different air pressures to examine the conditions of the patient's stomach [20,21]. A study explores discrimination levels of the fingers and wrist movements while utilizing pneumatic actuators in the form of assistive gloves.…”
Section: Upper Limb-based Soft Actuators Utilized During the Dexterou...mentioning
confidence: 99%
“…The soft actuator composition also covers the artificial pneumatic gel muscles (PGMs) utilized to examine the muscle loading and unloading effects for all motions of the upper limb [19]. Some research utilizes soft robots during fluoroscopy and x-ray examinations, including pneumatic flexible microactuator (FMA)-based towel or pillow controlled with different air pressures to examine the conditions of the patient's stomach [20,21]. A study explores discrimination levels of the fingers and wrist movements while utilizing pneumatic actuators in the form of assistive gloves.…”
Section: Upper Limb-based Soft Actuators Utilized During the Dexterou...mentioning
confidence: 99%
“…Soft miniature robots [1], ranging from nanometres to millimetres, have attracted considerable attention in recent years due to the rapid advances in material fabrication and mechanical manufacture technologies [2,3]. Soft robots have an unmatched advantage to adapt various unstructured environments with respect to their rigid counterparts, demonstrating unprecedented unique applications prospects [4][5][6], such as precise surgery [7], targeted examination [8], under-water explorations [9] and drug delivery [10]. Moreover, soft robots can exhibit safe interaction performances with human body and great flexibility to respond because of their high compliance and adaptability [11].…”
Section: Introductionmentioning
confidence: 99%
“…Because pneumatic actuators have compliance, they are widely researched for human support devices [1][2][3][4][5]. Recently, the actuators are examined as the application of artificial muscles and soft actuators [6][7][8][9][10]. However, it is difficult to control pneumatic equipment since air is compressible and has nonlinear characteristics.…”
Section: Introductionmentioning
confidence: 99%