Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2006
2006
2014
2014

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(12 citation statements)
references
References 1 publication
0
12
0
Order By: Relevance
“…a sealing surface sampling-probe (SSSP) 119 and a liquid microjunction surface-sampling probe (LMJ-SSP). 120 While the emphasis in each case has been on coupling with ESI, the use of APCI has been demonstrated, 121,122 and there is no fundamental limitation to using other liquid introduction ionization sources such as APPI, ICP, or any other. Once in solution and carried into the source, the analyte ionization is governed by the processes fundamental to the particular ionization source.…”
Section: Liquid Extraction Surface-sampling Probe/ionizationmentioning
confidence: 99%
See 1 more Smart Citation
“…a sealing surface sampling-probe (SSSP) 119 and a liquid microjunction surface-sampling probe (LMJ-SSP). 120 While the emphasis in each case has been on coupling with ESI, the use of APCI has been demonstrated, 121,122 and there is no fundamental limitation to using other liquid introduction ionization sources such as APPI, ICP, or any other. Once in solution and carried into the source, the analyte ionization is governed by the processes fundamental to the particular ionization source.…”
Section: Liquid Extraction Surface-sampling Probe/ionizationmentioning
confidence: 99%
“…119,121 However, the probe and elution concept by Luftmann 119 has been most often used because it is available commercially.…”
Section: Sealing Surface-sampling Probementioning
confidence: 99%
“…22 The elution-head-based approach was demonstrated on TLC plates silica gel 60 coupled to MS via the Eluchrom automatic elution system (available from CAMAG, Muttenz, Switzerland until 1992), which eluted up to six zones in parallel ( Figure 2). 24 With specially constructed knives on the bottom of the elution head, a channel was cut around the zone of interest on the TLC silica gel plate. The scored plate was placed on the Eluchrom unit, and a Teflon elution head was exactly placed over the adsorbent-free glass circle.…”
Section: Adsorbent-free Seal (Eluchrom)mentioning
confidence: 99%
“…[25] Various desorption-based techniques have been reported for coupling, e.g., fast atom bombardment (FAB), [26] secondary ion mass spectrometry (SIMS), [27] matrix assisted laser desorption=ionization (MALDI), [28][29][30] desorption electrospray ionization (DESI), [31] electrospray-assisted laser desorption=ionization mass spectrometry (ELDI-MS), [32] continuous wave diode laser desorption=atmospheric pressure chemical ionization (LD-APCI), [33] direct analysis in real time (DART), [34] easy ambient sonic-spray ionization mass spectrometry (EASI-MS), [35,36] and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). [37,38] Elution-based approaches include an automatic sampling surface probe coupled with electrospray ionization (ESI) by a micro-junction, [39] or elution-based interfaces coupled to APCI [40] or ESI. [41,42] The latter approach was successfully proven for qualitative [19,43,44] and quantitative analysis, [34,42] and, hence, it was used in this work.…”
Section: Introductionmentioning
confidence: 99%