Abstract: Stents that have been implanted to preserve the results of vascular dilatation are frequently affected by in-stent restenosis, which ideally should be followed up by a noninvasive diagnostic modality. Active MRI stents can enable this kind of follow-up, while normal metallic stents can not. The prototype stents investigated in this study were designed as electric resonating circuits without a direct connection to the MR imager, and function as inductively coupled transmit coils. The model of a long solenoid co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(22 citation statements)
references
References 29 publications
0
22
0
Order By: Relevance
“…The pumping signal used to power the parametric circuit creates an additional heat source besides the NMR excitation pulse (14). For our prototype circuit, the output power level from the pumping loop was 13 dBm, which yielded an effective power received by the resonator of 0 dBm after attenuation was taken into account.…”
Section: Discussionmentioning
confidence: 99%
“…The pumping signal used to power the parametric circuit creates an additional heat source besides the NMR excitation pulse (14). For our prototype circuit, the output power level from the pumping loop was 13 dBm, which yielded an effective power received by the resonator of 0 dBm after attenuation was taken into account.…”
Section: Discussionmentioning
confidence: 99%
“…During RF excitation, the WAND was wirelessly decoupled by the excitation field, which can strongly modulate the capacitance of its constituting varactors. As a result, there would be negligible RF‐induced heating or excitation angle over‐flipping as are normally encountered in inductively coupled implantable resonators . During signal reception, less than 10 mW of power was required on the pumping loop to operate the WAND at 0.6 dBm below its oscillation threshold for efficient signal amplification.…”
Section: Methodsmentioning
confidence: 99%
“…Several medical implants have been studied through numerical simulations, like stents [15][16][17][18][19][20][21][22][23]. The real CAD model can sometimes be modeled [21], showing a good correspondence between experimental and numerical results; otherwise the geometry is simplified [15,18], which could lead to a different behavior regarding RF heating compared to reality.…”
Section: The Years 2000 Have Been a Turning Point With New Astm (Amermentioning