1997
DOI: 10.1142/s0217984997001341
|View full text |Cite
|
Sign up to set email alerts
|

On the Possibility of the Creation of Radically New Type Detectors of Particles and Radiation Based on High-Tc Superconductors

Abstract: Some aspects of high-T c superconductors (HTSC) electrophysical properties, which could be successfully applied to the detection of particles and radiation are discussed. The possibilities and the perspectives of the creation of completely new type detectors of elementary particles and ionizing radiation, based on HTSC materials, are considered. At this, the use of the unusual open-flat measuring (pick-up) coils made of, in particular, the HTSC materials, as a detecting element in known tunnel diode oscillato… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
7
0

Year Published

1998
1998
2012
2012

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…Such superiority in the resolution of the improved LC resonator method makes it attractive for a creation of various new types of high resolution testing and detecting techniques. 23,28,29 The measured change in the oscillator resonant frequency, ␦F, can then be linearly related to the length, S , of magnetic shielding by the sample of the testing electromagnetic field generated by a flat coil: S ϭϪG•␦F. In general, the measured magnetic shielding length S , we deal with at the experiments, is not the same as the superconducting London penetration depth, L , in the Meissner state or the pinning penetration depth, pin , in the mixed state.…”
Section: Improved ''Lc Resonator'' Method: Open-flat Coil Magnetomentioning
confidence: 99%
See 3 more Smart Citations
“…Such superiority in the resolution of the improved LC resonator method makes it attractive for a creation of various new types of high resolution testing and detecting techniques. 23,28,29 The measured change in the oscillator resonant frequency, ␦F, can then be linearly related to the length, S , of magnetic shielding by the sample of the testing electromagnetic field generated by a flat coil: S ϭϪG•␦F. In general, the measured magnetic shielding length S , we deal with at the experiments, is not the same as the superconducting London penetration depth, L , in the Meissner state or the pinning penetration depth, pin , in the mixed state.…”
Section: Improved ''Lc Resonator'' Method: Open-flat Coil Magnetomentioning
confidence: 99%
“…23,24 As a consequence, we created a number of TD oscillators ͑the OFC magnetometers͒ with highly stable frequency and low power ͑Ͻ10 W͒ for different applications. They operate between 4.2 and 300 K with a frequency stability ␦F/Fϳ10 Ϫ6 -10 Ϫ7 /h ͑depending on the level of diffused external rf fields near the testing coil͒ at 300 K and a better stability than ␦F/Fϳ10 Ϫ7 /h below 100 K under the temperature stability better than a few mK/h ͑see Fig.…”
Section: Improved ''Lc Resonator'' Method: Open-flat Coil Magnetomentioning
confidence: 99%
See 2 more Smart Citations
“…ment of the resolution of measurements by 3-4 orders of magnitude (especially, in studies of thin, plate-like HTS materials [1,[3][4][5][6][7][8]). For comparison, typical values of the filling factor for solenoid coils are 10  4 10  3 for the said samples.…”
mentioning