1995
DOI: 10.1016/s0022-0736(05)80054-8
|View full text |Cite
|
Sign up to set email alerts
|

On the potential of the wilson central terminal with respect to an ideal reference for unipolar electrocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Estimates of the actual potential at WCT have been made with respect to an infinite reference using body surface potential data, and they are close enough to each other to be considered equivalent. 7 WCT is also used as the reference for unipolar intracardiac signals, and this will be discussed in detail later. Several approximations exist when acquiring unipolar signals.…”
Section: Overview Of a Typical Data Acquisition Systemmentioning
confidence: 99%
“…Estimates of the actual potential at WCT have been made with respect to an infinite reference using body surface potential data, and they are close enough to each other to be considered equivalent. 7 WCT is also used as the reference for unipolar intracardiac signals, and this will be discussed in detail later. Several approximations exist when acquiring unipolar signals.…”
Section: Overview Of a Typical Data Acquisition Systemmentioning
confidence: 99%
“…Before delving into the full explanation of our method, we must mention that Wilson’s hypothesis and the related triangle to star transformation has been challenged at both the theoretical [ 8 , 9 , 10 , 11 , 12 , 13 ] and practical level [ 2 , 3 , 6 , 10 , 11 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 ] several times in the past 80 years, with several researchers confirming that, contrary to what Wilson’s principal postulates [ 1 , 22 , 23 ], the amplitude of the WCT can be comparable to (or even larger than) the limb leads, and can exhibit variability during the cardiac cycle similar to any other ECG signal [ 2 , 8 , 10 , 16 , 24 , 25 , 26 , 27 , 28 ]. Still, as already mentioned, one may note that the original instrument that both Einthoven and Wilson used to formalize the triangular ECG model and the WCT was measuring the current impressed by the heart to the body surface, while modern electrocardiography uses voltage amplifiers [ 28 ].…”
Section: Methodsmentioning
confidence: 99%
“…Since then efforts are made to understand the error introduced by using the WCT in ECG-measurements [145][146][147][148] and efforts were taken to derive a zero potential based on the measurements [149]. In 2018 Moeinzadeh et al [150] tried to minimise the fluctuations of the WCT in time by finding (constant) weights for the individual measurement electrodes with a genetic algorithm.…”
Section: Referencing the Ecg In Timementioning
confidence: 99%