On the selection of the optimal plasticizer for calix[n]arene-based ion-selective electrodes: Possible correlation between the ion selectivity and the ?softness? of the plasticizer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
6
0

Year Published

1996
1996
2011
2011

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 9 publications
3
6
0
Order By: Relevance
“…The overall precision of extraction results attains some ±0.2 kJ/mol (with exception of H + ), whereas mean values from electrochemical measurements do not exceed a precision of ±1 kJ/mol. The obtained extraction results are corroborated by almost complete agreement with electrochemical values obtained with PVC membrane . Calculated values in a paper 27 reasonably agree with the extraction data.…”
Section: Resultssupporting
confidence: 80%
See 2 more Smart Citations
“…The overall precision of extraction results attains some ±0.2 kJ/mol (with exception of H + ), whereas mean values from electrochemical measurements do not exceed a precision of ±1 kJ/mol. The obtained extraction results are corroborated by almost complete agreement with electrochemical values obtained with PVC membrane . Calculated values in a paper 27 reasonably agree with the extraction data.…”
Section: Resultssupporting
confidence: 80%
“…Dioctyl Sebacate, DOS. This is another solvent largely used in ISEs aimed at measurements of cation concentrations, e.g., its selectivity in the absence of any cation complex-forming agent was measured for alkali metal cations . The selectivity span is much lower than that for NPOE, and reported values read from Figure of ref are about log K pot Na,M = 0.4 for Cs + and as low as ca.…”
Section: Resultsmentioning
confidence: 93%
See 1 more Smart Citation
“…Additionally, the membrane plasticizer can also have a dramatic effect on both the upper and lower detection limits of ISEs [19]. Several studies have examined the effects of plasticizers on the potentiometric performance of ISEs [18,20,21].…”
Section: Introductionmentioning
confidence: 99%
“…It has been asserted that these observations are due to the differences in polarity or dielectric constants (ε NPOE,mem =14, ε DOS,mem = 4.8) of the two types of plasticized PVC membrane [32,33,34]. Alternatively, a study of the effect of more than 15 plasticizers on the selectivity of ISEs constructed from the same ionophore demonstrated a relationship between the hard/soft character of the plasticizing molecules and observed selectivity [35]. Similar influences have been observed for detection limits and degrees of ion pairing, with both parameters being dependent on the nature of the plasticizer employed [29,36,37].…”
Section: Components Of Ion-selective Electrodesmentioning
confidence: 91%