2006
DOI: 10.5194/acp-6-4801-2006
|View full text |Cite
|
Sign up to set email alerts
|

On the time-averaging of ultrafine particle number size spectra in vehicular plumes

Abstract: Abstract. Ultrafine vehicular particle (<100 nm) number size distributions presented in the literature are mostly averages of long scan-time (∼30 s or more) spectra mainly due to the non-availability of commercial instruments that can measure particle distributions in the <10 nm to 100 nm range faster than 30 s even though individual researchers have built faster (1-2.5 s) scanning instruments. With the introduction of the Engine Exhaust Particle Sizer (EEPS) in 2004, high time-resolution (1 full 32-channel sp… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…The CPC and SMPS are widely used for measurement of PNCs, but it is rare for an EEPS to be used in the field (e.g., Jacobson et al, 2005;Kittelson et al, 2006;Yao et al, 2006;Minoura et al, 2009). We compared total PNCs and size distributions obtained in a roadside environment with an EEPS with those obtained with CPCs and SMPSs to allow our data to be compared with data from the literature obtained by other instruments.…”
Section: Comparison Of Instruments For Measuring Particle Number Concmentioning
confidence: 99%
“…The CPC and SMPS are widely used for measurement of PNCs, but it is rare for an EEPS to be used in the field (e.g., Jacobson et al, 2005;Kittelson et al, 2006;Yao et al, 2006;Minoura et al, 2009). We compared total PNCs and size distributions obtained in a roadside environment with an EEPS with those obtained with CPCs and SMPSs to allow our data to be compared with data from the literature obtained by other instruments.…”
Section: Comparison Of Instruments For Measuring Particle Number Concmentioning
confidence: 99%
“…FMPSs were used to continuously measure PNSDs with mobility diameters ranging from 5.6 to 560 nm at 1 s time resolution, facilitating the investigation of rapid changes in nanoparticles due to formation and mixing from different sources (Yao et al, 2005(Yao et al, , 2006b. Conductive tubes (TSI 3/8 in., each cut to a length of 2.8 m) were used for sampling at the two sites.…”
Section: Sampling Instrumentsmentioning
confidence: 99%
“…Early developments by Mirme (1994) at Tartu University and Biskos et al (2005), led to the commercialized systems available today, such as the EEPS by TSI and the DMS500 by Cambustion. In recent years, both the EEPS and DMS500 have been widely used for emission measurement and characterization (Liu et al 2005;Rubino et al 2005;Yao et al 2006;Zervas and Dorlhene, 2006;Zheng et al 2012). The two instruments have multiple electrometers downstream of a corona charger to measure size distributions.…”
Section: Introductionmentioning
confidence: 99%